- 1 - 

ReServ4WP

Overview:

ReServ4WP Video Surveillance UPS unit is designed to provide power for 24VAC and 12VDC cameras during normal or power outage 
conditions. True sine wave regulated AC outputs and/or regulated DC outputs.

Specifications:

Stand-by Specifications:

Stand-by Batteries

4A (100VA) load at 24VAC and 1A load at 12VDC max.

Two (2) 12VDC/7AH

45 minutes

Two (2) 12VDC/12AH

90 minutes

Installation Instructions:

This installation should be made by qualified service personnel and should conform to the National Electrical Code and all local codes. 
This product contains no serviceable parts.
1.  Remove back plate inside the enclosure by removing four (4) mounting screws.
2.  Mark and drill desired knockouts on the enclosure to facilitate wiring
 

(Fig. 1, pg. 1).

 

Note: It is required to use UL Listed outdoor rated conduit hubs with a 

 

minimum outdoor rating of NEMA4X.

3.  Secure back plate inside the enclosure with four (4) mounting screws.
4.  Mount unit in the desired location with the appropriate fasteners utilizing the 
 

holes on the flanges (pg. 8). Secure enclosure to earth ground. 

 

Note: This product needs to be secured to the building/pole before operation.

5.  Connect AC power mains to the terminals marked [L] and [N]
 

(Fig. 2, pg. 3).

 

Use 18 AWG or larger for all power connections (Battery, output)

 

(Fig. 2, pg. 3).

 

Use 18 AWG to 22 AWG for power-limited circuits

 

(AC Fail/Low Battery reporting) (Fig. 2, pg. 3).

 

Note: A readily accessible disconnect device shall be incorporated in the 

 

building installation wiring.

6.  The LEDs on the power supply board will illuminate when AC power is present.
7.  Measure output voltage before connecting cameras/devices to outputs.
 

This helps avoiding potential damage.

8.  Connecting Fluidmesh Wireless Radio/Bosch Autodome:
 

Connect 12VDC Fluidmesh Wireless Radio to the terminals marked [P 1-2, N 1-2] (Fig. 2, pg. 3).

 

Connect 24VAC Bosch Autodome to the terminals marked [15-16] (Fig. 2, pg. 3).

9.  Connect batteries to the terminals marked [+ BAT –] (Fig. 2, pg. 3). Use two (2) 12VDC batteries connected in series for 24VDC 
 

operation (battery leads included).

 

Use batteries - Casil CA1270 (12V/7AH), Genesis NP7-12 (12V/7AH), Ultratech UT1270 (12V/7AH).

10.  Connect appropriate signaling notification devices to AC FAIL & BAT FAIL (Fig. 2, pg. 3) supervisory relay outputs.
11.  The power LEDs on the unit for Outputs 1-2 and 15-16 will illuminate when AC power is present (Fig. 2, pg. 3).
 

Note: If any of the power LEDs are not illuminated, the cause may be due to the following:

 

  a. AC mains and battery fail.

 

  b. One (1) or more power output PTCs are tripped due to a short circuit or overload condition.

 

  c. Unit damaged/defective.

Input:

•  115VAC, 60Hz, 3.5A.

Output:

•  PTC protected auto-resettable outputs:
  - 24VAC @ 4A max.
  - 12VDC @ 1A.

Battery Backup:

•  Built-in charger for sealed lead acid or gel type batteries. 
•  Automatic switchover to stand-by battery when AC fails.

Supervision:

•  AC fail and low battery supervision (form “C” contacts). 

Visual and Audio Indicators:

•  AC/DC power LED indicators.

Visual Indicators:

•  Individual power output LED indicators.
•  Low voltage input and Shutdown LED indicators.

Additional Features:

•  True sine wave regulated AC outputs and regulated DC outputs.
•  Unit maintains camera synchronization. 
•  Ease of installation saves time and eliminates costly labor.

Enclosure Dimensions:

•  NEMA4 / IP66 Rated enclosure accommodates up to
  two (2) 12VDC/7AH batteries.
  17.375” x 12” x 6.5” (441.3mm x 304.8mm x 165.1mm).

ReServ4WP

Outdoor Video Surveillance UPS

Right Panel

Left Panel

Suggested Locations 

for Wire Entries

Bottom Panel

Fig. 1

Summary of Contents for ReServ4WP

Page 1: ...tputs This helps avoiding potential damage 8 Connecting Fluidmesh Wireless Radio Bosch Autodome Connect 12VDC Fluidmesh Wireless Radio to the terminals marked P 1 2 N 1 2 Fig 2 pg 3 Connect 24VAC Bosch Autodome to the terminals marked 15 16 Fig 2 pg 3 9 Connect batteries to the terminals marked BAT Fig 2 pg 3 Use two 2 12VDC batteries connected in series for 24VDC operation battery leads included ...

Page 2: ...se terminals L to hot N to neutral DC 24VDC output AC FAIL NO C NC Form C dry contacts used to instantaneously signal the loss AC to local annunciation devices With AC present terminals marked NO and C are open NC and C are closed When loss of AC occurs terminals marked NO and C are closed NC and C are open BAT FAIL NO C NC Form C dry contacts used to signal low battery voltage or loss of battery ...

Page 3: ...ersonnel This product contains no serviceable parts PMK1 is intended for use with Altronix outdoor rated power supplies or accessories housed in WP1 WP2 WP3 and WP4 enclosures Brackets are designed for use with the Wormgear Quick Release Straps two included 1 Thread one 1 wormgear quick release strap through the slots on the back of a mounting bracket Fig 4 pg 4 2 Once the desired height of the to...

Page 4: ...41 3mm 10 254mm 16 75 425 45mm 12 304 8mm 10 875 276 2mm 14 875 377 83mm 0 3125 7 9375mm 0 5 12 7mm 4 5 114 3mm MEMBER Fig 4 Fig 5 Fig 6 5 Mount enclosure onto the top bracket by inserting bolts through flange of the enclosure and into the bracket tightening bolts with a 7 16 hex socket Fig 7 pg 4 6 Tighten the straps of the bottom bracket down by sliding the open end of the strap through the lock...

Reviews: