Tango8P(CB) - PoE Driven Multi-Output Power Supply
- 5 -
LED Diagnostics:
Tango1B
LED
ON
BLINKING
Input
Input voltage is present .
Input voltage not present .
Battery
Normal operating condition .
Battery is low or missing .
PoE
Indicates Class .
Refer to table below Classes 3-8
Supervision
PoE Fail or BAT Fail .
NC dry contact 30V 1A (not an LED)
Class
Green
Red
Blue
Class
Green
Red
Blue
Class 1
–
–
–
Class 5
On
Off
On
Class 2
–
–
–
Class 6
On
Off
On
Class 3
Off
Off
Off
Class 7
On
On
On
Class 4
Off
On
Off
Class 8
On
On
On
PDS8:
LED
ON
Green
12VDC Output .
Green and Red 24VDC Output .
Terminal Identification:
Tango1B
Terminal/RJ45 Legend
Function/Description
PoE+ Data Input
IEEE802 .3bt Input (Fig. 2b, pg. 4) .
Data Output
Passes Data to Switch (Fig. 2a, pg. 4)
C FAIL NC
Power and Battery Fail (Fig. 2c, pg. 4) .
+ 12V –
12VDC output (Fig. 2d, pg. 4) .
+ 24V –
24VDC output (Fig. 2e, pg. 4) .
+ BAT –
Lithium Iron Phosphate battery backup (Fig. 2f, pg. 4) .
8-Pin Connector (Fig. 2g, pg. 4)
Facilitates electrical connection to PDS8(CB) .
PDS8:
Terminal Legend
Function/Description
+ INP1 –
Factory connected to Tango1B . Do not use these terminals .
+ INP2 –
Factory connected to Tango1B . Do not use these terminals .
P [OUT1-OUT8]
Positive DC power outputs .
N [OUT1-OUT8]
Negative DC power outputs .