background image

 

Tango1B - PoE Driven Power Supply with Lithium Battery Backup 

- 3 -

Fig. 1 - Tango1B configuration

 

Wiring:

Use 18 AWG or larger for all low voltage power connections.

LED Diagnostics:

LED

ON

BLINKING

Input

Input voltage is present.

Input voltage not present.

Battery

Normal operating condition.

Battery is low or missing.

PoE

Indicates Class.

Refer to table below Classes 3-8

Supervision

PoE Fail or BAT Fail.

NC dry contact 30V 1A (not an LED)

PoE Input Class (W)

Green

Red

Blue

Class 1 (3.84)

---

---

---

Class 2 (6.49)

---

---

---

Class 3 (13.00)

Off

Off

Off

Class 4 (25.50)

Off

On

Off

Class 5 (40.00)

On

Off

On

Class 6 (51.00)

On

Off

On

Class 7 (62.00)

On

On

On

Class 8 (71.30)

On

On

On

Terminal Identification:

Terminal/RJ45 Legend

Function/Description

PoE+ Data Input

IEEE802.3bt Input (Fig. 1b, pg. 3).

Data Output

Passes Data to Switch (Fig. 1a, pg. 3)

C FAIL NC

Power and Battery Fail (Fig. 1c, pg. 3). In normal conditions this relay
is closed and in trouble conditions this relay open.

+ 12V –

12VDC output (Fig. 1d, pg. 3).

+ 24V –

24VDC output (Fig. 1e, pg. 3).

+ BAT –

Lithium Iron Phosphate battery backup (Fig. 1f, pg. 3).

8-Pin Connector (Fig. 1g, pg. 3) Facilitates electrical connection to PDS8(CB) or ACMS8(CB).

1a

1b

1c

1d

1e

1f

1g

Reviews: