background image

T2HCK5F

Up to 16 Door Kit

Fully assembled kit includes:

  -  Trove2 enclosure with THC2 Altronix/Hartmann Controls backplane

  -  One (1) eFlow102NB - Power Supply/Charger

T2HCK7F8

8 Door Kit with Fused Outputs 

Fully assembled kit includes:

  -  Trove2 enclosure with THC2 Altronix/Hartmann Controls backplane

  - One (1) eFlow104NB - Power Supply/Charger

  -  One (1) ACMS8 - Dual Input Fused Access Power Controller

  -  One (1) VR6 - Voltage Regulator
  -  One (1) PDS8 - Dual Input Fused Power Distribution Module

T2HCK75F

Up to 16 Door Kit

Fully assembled kit includes:

  -  Trove2 enclosure with THC2 Altronix/Hartmann Controls backplane

  -  One (1) eFlow104NB - Power Supply/Charger

  -  One (1) eFlow102NB - Power Supply/Charger

T2HCK75F16

Up to 16 Door Kit with Fused Outputs

Fully assembled kit includes:

  -  Trove2 enclosure with THC2 Altronix/Hartmann Controls backplane

  -  One (1) eFlow104NB - Power Supply/Charger

  -  One (1) eFlow102NB - Power Supply/Charger

  -  Two (2) ACMS8 - Dual Input Fused Access Power Controllers

Access & Power Integration

Rev. T2HC052820

Installing Company:  _____________________ Service Rep. Name:  __________________________________________ 

Address:  ________________________________________________________  Phone #:  _________________________

All registered trademarks are property of their respective owners. 

More than just power.™

Installation Guide

All components of these Trove kits are UL Listed sub-assemblies.
Please refer to the included corresponding Sub-Assembly Installation Guides for further information.

Summary of Contents for Trove T2HCK5F

Page 1: ... One 1 eFlow102NB Power Supply Charger T2HCK75F16 Up to 16 Door Kit with Fused Outputs Fully assembled kit includes Trove2 enclosure with THC2 Altronix Hartmann Controls backplane One 1 eFlow104NB Power Supply Charger One 1 eFlow102NB Power Supply Charger Two 2 ACMS8 Dual Input Fused Access Power Controllers Access Power Integration Rev T2HC052820 Installing Company ______________________ Service ...

Page 2: ... 13 2 10 03 13 2 Hardware and Accessories Installation Instructions Wiring methods shall be in accordance with the National Electrical Code NFPA 70 ANSI and with all local codes and authorities having jurisdiction Product is intended for indoor use only 1 Remove backplane from enclosure Do not discard hardware 2 Mark and predrill holes in the wall to line up with the top three keyholes in the encl...

Page 3: ... spacers utilizing provided 5 16 pan head screws Fig 2a pg 3 4 Fasten backplane to Trove2 enclosure utilizing lock nuts provided NC C NO NC C NO AC FAIL BAT FAIL TRIGGER EOL SUPERVISED AC DC AC1 NO GND RESET AUX BAT L G N 1 min enable 2 hr disable DC Altronix eFlow102NB PRS_MASTER Metal Spacer PRS_TDM or PRS_IO8 Metal Spacer PRS_TDM or PRS_IO8 Metal Spacer PRS_TDM or PRS_IO8 Metal Spacer PRS_TDM o...

Page 4: ...ASTER Metal Spacer PRS_TDM or PRS_IO8 Metal Spacer PRS_TDM or PRS_IO8 Metal Spacer PRS_TDM or PRS_IO8 Metal Spacer PRS_TDM or PRS_IO8 Metal Spacer PRS_TDM or PRS_IO8 Metal Spacer PRS_TDM or PRS_IO8 Metal Spacer PRS_TDM or PRS_IO8 Metal Spacer PRS_TDM or PRS_IO8 Metal Spacer PRS_MASTER Metal Spacer Altronix eFlow104NB DC BAT L G N PWR1 PWR2 COM COM PWR2 PWR1 PWR2 PWR1 Altronix ACMS8 INP1 OFF IN1 IN...

Page 5: ...ng provided 5 16 pan head screws Fig 4a pg 5 4 Fasten backplane to Trove2 enclosure utilizing lock nuts provided Altronix eFlow104NB DC BAT L G N NC C NO NC C NO AC FAIL BAT FAIL TRIGGER EOL SUPERVISED AC DC AC1 NO GND RESET AUX BAT L G N 1 min enable 2 hr disable DC Altronix eFlow102NB PRS_MASTER Metal Spacer PRS_TDM or PRS_IO8 Metal Spacer PRS_TDM or PRS_IO8 Metal Spacer PRS_TDM or PRS_IO8 Metal...

Page 6: ...n backplane to Trove2 enclosure utilizing lock nuts provided DC BAT L G N NC C NO NC C NO AC FAIL BAT FAIL TRIGGER EOL SUPERVISED AC DC AC1 NO GND RESET AUX BAT L G N 1 min enable 2 hr disable DC PWR1 PWR2 COM COM PWR2 PWR1 PWR2 PWR1 PWR1 PWR2 COM COM PWR2 PWR1 PWR2 PWR1 PRS_MASTER Metal Spacer PRS_TDM or PRS_IO8 Metal Spacer PRS_TDM or PRS_IO8 Metal Spacer PRS_TDM or PRS_IO8 Metal Spacer PRS_TDM ...

Page 7: ...ures UL Listed in the U S and Canada Local or remote control of up to 2 two Altronix eFlow power output s via LAN and or WAN Monitor real time diagnostics DC output voltage output current AC battery status service input trigger state change output state change and unit temperature Access control and user managment Restrict read write Restrict users to specific resources Two 2 integral network cont...

Page 8: ...D approximate 27 25 x 21 5 x 6 5 692 2mm x 552 5mm x 165 1mm 6 75 171 5mm 8 25 209 5mm 8 00 203 2mm 2 00 50 8mm 2 00 50 8mm 1 25 31 8mm 1 25 31 8mm 5 25 133 4mm 5 25 133 4mm 7 00 177 8mm 1 25 31 8mm 6 25 158 8mm 19 80 502 9mm 1 00 25 4mm 27 685 8mm 1 5 38 1mm 2 00 50 8mm 2 00 50 8mm 3 5 88 9mm 3 5 88 9mm 21 50 546 1mm 5 25 133 35mm 5 25 133 35mm 6 25 158 8mm 1 25 31 8mm 0 85 21 6mm 0 5625 14 3mm 2...