THC2 Kits
- 5 -
T2HCK75F: Configuration of Hartmann Controls Boards:
1. Align the Hartmann Controls boards on the backplane to match the boards’ mounting holes with corresponding pems.
2. Fasten spacers (provided) to pems that match the hole pattern for Hartmann Control boards (Fig. 4, 4a, pg. 5).
Note: Hartmann Controls boards must be properly grounded.
Please use provided metal spacers for the lower right mounting holes (Fig. 4, pg. 5).
3. Mount Hartmann Controls boards to spacers utilizing provided 5/16” pan head screws (Fig. 4a, pg. 5).
4. Fasten backplane to Trove2 enclosure utilizing lock nuts (provided).
Altronix - eFlow104NB
– DC
+
– BAT
+
L G N
NC C NO NC C NO
AC FAIL
BAT FAIL
TRIGGER EOL
SUPERVISED
AC DC
AC1
NO GND
RESET
+ AUX -
---
BA
T
+
L G N
1 min enable
2 hr disable
---
DC
+
Altronix - eFlow102NB
PRS_MASTER
Metal Spacer
PRS_TDM or PRS_IO8
Metal Spacer
PRS_TDM or PRS_IO8
Metal Spacer
PRS_TDM or PRS_IO8
Metal Spacer
PRS_TDM or PRS_IO8
Metal Spacer
PRS_TDM or PRS_IO8
Metal Spacer
PRS_TDM or PRS_IO8
Metal Spacer
PRS_TDM or PRS_IO8
Metal Spacer
PRS_TDM or PRS_IO8
Metal Spacer
PRS_MASTER
Metal Spacer
Pem
Spacer
Power Supply or
Sub-Assembly
Backplane
Pan Head
Screw
Fig. 3a
Fig. 3