T3MK75F16V

16 Door Kit with Fused Outputs

Fully assembled kit includes:

  -  Trove3 enclosure with TM3 Altronix/Mercury backplane

  -  One (1) eFlow104NBV - Power Supply/Charger

  -  One (1) eFlow102NBV - Power Supply/Charger

  -  Two (2) ACM8 - Fuse Protected Access Power Controllers

  -  One (1) PD8UL - Fuse Protected Power Distribution Module

  -  One (1) Rocker Switch Bracket with Two (2) Rocker Switches

  

T3MK77F16V

16 Door Kit with Fused Outputs

Fully assembled kit includes:

  -  Trove3 enclosure with TM3 Altronix/Mercury backplane

  -  Two (2) eFlow104NBV - Power Supply/Chargers

  -  Two (2) ACM8 - Fuse Protected Access Power Controllers

  -  Two (2) PD8UL - Fuse Protected Power Distribution Modules

  -  One (1) Rocker Switch Bracket with Two (2) Rocker Switches

T3MK75F16DV

16 Door Kit with PTC Outputs

Fully assembled kit includes:

  -  Trove3 enclosure with TM3 Altronix/Mercury backplane

  -  One (1) eFlow104NBV - Power Supply/Charger

  -  One (1) eFlow102NBV - Power Supply/Charger

  -  Two (2) ACM8CB - PTC Protected Access Power Controllers

  -  One (1) PD8ULCB - PTC Protected Power Distribution Module

  -  One (1) Rocker Switch Bracket with Two (2) Rocker Switches

  

T3MK77F16DV

16 Door Kit with PTC Outputs

Fully assembled kit includes:

  -  Trove3 enclosure with TM3 Altronix/Mercury backplane

  -  Two (2) eFlow104NBV - Power Supply/Chargers

  -  Two (2) ACM8CB - PTC Protected Access Power Controllers

  -  Two (2) PD8ULCB - PTC Protected Power Distribution Modules

  -  One (1) Rocker Switch Bracket with Two (2) Rocker Switches

Access & Power Integration

Rev. T3MKV030320

Installing Company:  _____________________ Service Rep. Name:  __________________________________________ 

Address:  ________________________________________________________  Phone #:  _________________________

All registered trademarks are property of their respective owners. 

More than just power.™

Installation Guide

Please refer to the included corresponding Sub-Assembly Installation Guides for further information.

Summary of Contents for TROVE T3MK75F16V

Page 1: ...ne 1 eFlow104NBV Power Supply Charger One 1 eFlow102NBV Power Supply Charger Two 2 ACM8CB PTC Protected Access Power Controllers One 1 PD8ULCB PTC Protected Power Distribution Module One 1 Rocker Switch Bracket with Two 2 Rocker Switches T3MK77F16DV 16 Door Kit with PTC Outputs Fully assembled kit includes Trove3 enclosure with TM3 Altronix Mercury backplane Two 2 eFlow104NBV Power Supply Chargers...

Page 2: ...for convenient access Enclosure Dimensions H x W x D 36 12 x 30 125 x 7 06 917 5mm x 768 1mm x 179 3mm Installation Instructions Wiring methods shall be in accordance with the National Electrical Code NFPA 70 ANSI and with all local codes and authorities having jurisdiction Product is intended for indoor use only 1 Remove backplane from enclosure Do not discard hardware 2 Mark and predrill holes i...

Page 3: ... and depress onto snap on spacers Fig 2a pg 3 3 Mount backplane to enclosure with hardware Access Controller Position Chart for the Following Models Mercury Access Controller Pem Mounting EP1502 MR52 MR16IN MR16OUT A EP2500 MUX8 B EP1501 MR51e C MR52 D Altronix eFlow104NBV Altronix eFlow102NBV Altronix ACM8 CB Altronix ACM8 CB Altronix PD8UL CB D B B A A A A A A A A C RSB2 Bracket Rocker Switch Fi...

Page 4: ...depress onto snap on spacers Fig 3a pg 4 3 Mount backplane to enclosure with hardware Access Controller Position Chart for the Following Models Mercury Access Controller Pem Mounting EP1502 MR52 MR16IN MR16OUT A EP2500 MUX8 B EP1501 MR51e C MR52 D Altronix eFlow104NBV Altronix eFlow104NBV Altronix ACM8 CB Altronix ACM8 CB Altronix PD8UL CB Altronix PD8UL CB D B B A A A A A A A A C RSB2 Bracket Roc...

Page 5: ...T3MKV Kits 5 Notes ...

Page 6: ...tures UL Listed in the U S and Canada Local or remote control of up to 2 two Altronix eFlow power output s via LAN and or WAN Monitor real time diagnostics DC output voltage output current AC battery status service input trigger state change output state change and unit temperature Access control and user managment Restrict read write Restrict users to specific resources Two 2 integral network con...

Page 7: ...KV Kits 7 TM3 Dimensions 34 x 28 x 0 3125 863 6mm x 711 2mm x 7 9mm 0 45 11 4mm 2 5 63 5mm 2 50 8mm 13 5 342 9mm 13 5 342 9mm 13 5 342 9mm 25 635mm 0 156 3 96mm 1 0 25 4mm 1 0 25 4mm 34 863 6mm 28 711 2mm ...

Page 8: ...mm 14 01 355 9mm 1 25 31 8mm 1 55 39 4mm 1 78 45 2mm 1 25 31 8mm 1 07 27 2mm 1 10 27 9mm 2 50 8mm 10 75 273 1mm 10 75 273 1mm 10 62 269 8mm 2 00 50 8mm 10 75 273 1mm 10 75 273 1mm 10 62 269 8mm 36 12 917 5mm 33 63 854 2mm Altronix is not responsible for any typographical errors 140 58th Street Brooklyn New York 11220 USA phone 718 567 8181 fax 718 567 9056 web site www altronix com e mail info alt...