Overview:

Trove2KA2/Trove3KA3 accommodates various combinations of Keyscan boards with or without Altronix power supplies and accessories for 
access systems.

Specifications:

Agency Listings:

•  UL 294 - 6th edition: Line Security I, Destructive Attack I, Endurance IV, Stand-by Power II*.
  *Stand-by Power Level I if no battery is supplied.
•  This Class B digital apparatus complies with Canadian ICES-003. 
  Cet appareil numérique de la classe B est conforme á la norme NMB-003 du Canada.
•  CE European Conformity. 

Installation Instructions for Trove2/Trove3:

1. Remove backplane from enclosure prior to mounting (do not discard hardware).
2. Mark and predrill holes in the wall to line up with the top keyholes in the enclosure. Install the upper fasteners and screws in the wall 
  with the screw heads protruding. Place the enclosure’s upper keyholes over the screws; level and secure. 
  Mark the position of the lower holes. Remove the enclosure. Drill the lower holes and install the fasteners. 
  Place the enclosure’s upper keyholes over the upper screws. Install the lower screws and make 
  sure to tighten all screws (Enclosure Dimensions, pg. 6, 8).
3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired location,
  opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2” 
  from the right side (Fig. 1, pg. 2). Connect tamper switch wiring to the Access Control Panel 
  input or the appropriate UL Listed reporting device. 
  To activate alarm signal open the door of the enclosure.
4. Mount Altronix/Keyscan boards to backplane, refer to pages 3, 4.

Hardware:

Nylon Standoff  |           Metal Standoff   |           Pan Head Screw  |         Lock Nut

Trove2KA2

Trove2 enclosure with TKA2 Altronix/Keyscan backplane

•  Includes: tamper switch, cam lock, and mounting hardware.
  Enclosure Dimensions (H x W x D): 
  27.25” x 21.75” x 6.5” (692.2mm x 552.5mm x 165.1mm).

TKA2

Altronix/Keyscan backplane only

•  Includes mounting hardware.
  Dimensions (H x W x D): 
  25.375” x 19.375” x 0.3125” (644.5mm x 482.6mm x 7.9mm).

TKA2 accommodates a combination of the following:

Altronix Modules:

•  One (1) AL400ULXB2, AL600ULXB, AL1012ULXB, 
  AL1024ULXB2, eFlow4NB, eFlow6NB, eFlow102NB, or 
 eFlow104NB.
•  One (1) T16100, ACM4(CB), ACM8(CB), MOM5, PD4UL(CB), 
  PD8UL(CB), PDS8(CB), VR6.

Keyscan Modules:

•  One (1) CA250B, CA4500B, CA8500B, one (1) DPS-15,
 one (1) CIM.
•  Two (2) OCB8

Trove3KA3

Trove3 enclosure with TKA3 Altronix/Keyscan backplane

•  Includes: (2) tamper switches, cam lock, and mounting hardware.
  Enclosure Dimensions (H x W x D): 
  36.12” x 30.125” x 7.06” (917.5mm x 768.1mm x 179.3mm).

TKA3

Altronix/Keyscan backplane only

•  Includes mounting hardware.
  Dimensions (H x W x D): 
  34” x 28” x 0.3125” (863.6mm x 711.2mm x 7.9mm).

TKA3 accommodates a combination of the following:

Altronix Modules:

•  One (1) AL400ULXB2, AL600ULXB, AL1012ULXB, 
  AL1024ULXB2, eFlow4NB, eFlow6NB, eFlow102NB, or 
 eFlow104NB.
•  One (1) T16100, ACM4(CB), ACM8(CB), MOM5, PD4UL(CB), 
  PD8UL(CB), PDS8(CB), VR6.

Keyscan Modules:

•  Two (2) CA250B, CA4500B, CA8500B, two (2) DPS-15,
 two (2) CIM.
•  Four (4) OCB8

Fig. 1

Tamper Switch

(provided)

To Access Control Panel or

UL Listed Reporting Device

Edge of

Enclosure

Enclosure

Summary of Contents for Trove2KA2

Page 1: ..._____________ Phone __________________________ Access Power Integration Trove2KA2 Trove2 enclosure with Altronix Keyscan backplane TKA2 TKA2 Altronix Keyscan backplane only Trove3KA3 Trove3 enclosure...

Page 2: ...or the appropriate UL Listed reporting device To activate alarm signal open the door of the enclosure 4 Mount Altronix Keyscan boards to backplane refer to pages 3 4 Hardware Nylon Standoff Metal Stan...

Page 3: ...g 3 Note Please fasten metal and snap on standoffs in the proper locations Fig 2 pg 3 2 Mount boards to standoffs utilizing 5 16 pan head screws provided Fig 2 pg 3 3 Mount Altronix T16100 transformer...

Page 4: ...ease fasten metal and snap on standoffs in the proper locations Fig 3 pg 4 2 Mount boards to standoffs utilizing 5 16 pan head screws provided Fig 3 pg 4 3 Mount Altronix T16175 transformer to backpla...

Page 5: ...190 5mm 25 375 644 6mm 19 375 492 1mm 12 625 320 7mm 0 45 11 4mm 1 0 25 4mm 1 0 25 4mm 9 2 233 7mm 8 5 215 9mm 16 25 412 8mm 0 156 3 96mm 9 2 233 7mm 7 5 190 5mm 0 45 11 4mm TKA2 Dimensions H x W x D...

Page 6: ...8 25 209 54mm 8 00 203 2mm 1 5 38 1mm 1 25 31 75mm 0 85 21 59mm 0 85 21 59mm 1 00 25 4mm 2 00 50 8mm 1 25 31 75mm 2 00 50 8mm 2 00 50 8mm 5 25 133 35mm 5 25 133 35mm 7 00 177 79mm 2 00 50 8mm 2 00 50...

Page 7: ...7 Trove2KA2 Trove3KA3 TKA3 Dimensions 34 x 28 x 0 3125 863 6mm x 711 2mm x 7 9mm 23 584 2mm 27 685 8mm 11 5 292 1mm 6 5 165 1mm 8 55 217 2mm 28 711 2mm 34 863 6mm 11 5 292 1mm...

Page 8: ...imensions H x W x D approximate 36 12 x 30 125 x 7 06 917 5mm x 768 1mm x 179 3mm G G 2 00 50 8mm 8 75 222 3mm 8 75 222 3mm 8 62 219mm 7 06 179 3mm 1 25 31 8mm 1 25 31 8mm 2 00 50 8mm 7 12 222 25mm 9...