background image

 

- 2 - 

VertilLine24 Series Installation Guide

Overview:

Altronix VertiLine CCTV Rack Mount Power Supplies provide 24 power outputs in a space saving 1U EIA 19”    rack 

mount chassis which may be rack, wall or shelf mounted. The units feature individually selectable 24VAC and/or 

28VAC power outputs with surge suppression. VertiLine CCTV Rack Mount Power Supplies are also available in 

eight (8) and sixteen (16) output models with various power ratings. 

 Specifications:

Input:

•  Selectable 115VAC, 60Hz or 

  240VAC, 50/60Hz input.

Output:

•  Twenty-four (24) individually selectable 24VAC 

  or 28VAC power outputs with OFF position.

•  Twenty-four (24) external blade fuse or

  PTC protected outputs.

•  Surge suppression.

Features:

•  Twenty-four (24) power LED indicators.

Features 

(cont’d)

:

•  Removable terminal blocks with 

  locking screw flange.

•  Illuminated master power disconnect 

  circuit breaker with manual reset.

•  IEC 320 - 3-wire grounded line cord (detachable).

Mechanical:

•  Units can be rack, wall or shelf mounted.

•  Modular 1U standard EIA 19” rack mount chassis

•  Enclosure Dimensions (H x W x D approx.):

  1.625” x 19.125” x 8.5” 

  (41.3mm x 486mm x 216mm).

Twenty-four (24) Output Rack Mount Configuration 

Reference Chart:

Altronix

Model

Number

Output Voltage (VAC)

Total Output Current (Power)

Number of Outputs

Output Protection

Class 2 Rated Power- Limited Output Protection

Current (max. per output)

Fuse Rating

Main Fuse Rating

115VAC 60Hz  Input Current 230VAC 50/60Hz  Input Current

Agency Listings

UL Listings and File Numbers

VertiLine24

24VAC or

28VAC

10A

24

Fused

3A

3A

10A 3A 1.6A

UL Listed for

 Commercial 

CCTV 

Equipment

 (UL 2044). 

VertiLine24D

24VAC or 

28VAC

10A

24

PTC

2.5A

VertiLine246

24VAC or 

28VAC

14A

24

Fused

3A

3A

15A 4A 2.5A

VertiLine246D

24VAC or 

28VAC

14A

24

PTC

2.5A

WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or mois-
ture. This installation should be made by qualified service personnel and should conform to 
the National Electrical Code and all local codes.

Summary of Contents for VertiLine24 Series

Page 1: ... 24 PTC protected outputs VertiLine246D 24VAC or 28VAC 14A Twenty four 24 PTC protected outputs VertiLine24 Series CCTV Rack Mount Power Supplies Models Include Rev 031808 More than just power TM Installing Company ________________ Service Rep Name ___________________________________ Address ______________________________________________ Phone ___________________ Installation Guide ...

Page 2: ...0 3 wire grounded line cord detachable Mechanical Units can be rack wall or shelf mounted Modular 1U standard EIA 19 rack mount chassis Enclosure Dimensions H x W x D approx 1 625 x 19 125 x 8 5 41 3mm x 486mm x 216mm Twenty four 24 Output Rack Mount Configuration Reference Chart Altronix Model Number Output Voltage VAC Total Output Current Power Number of Outputs Output Protection Class 2 Rated P...

Page 3: ...ditional camera Outputs 2 24 After wiring is completed insert terminal block into the corresponding connector and secure by tightening the screws 10 Upon completion of the wiring set illuminated master power disconnect circuit breaker to the ON RESET position Fig 3 pg 6 11 The power LEDs Green on the faceplate for Outputs 1 24 will illuminate when AC power is present Fig 1a pg 4 If any of these LE...

Page 4: ...AC OFF 24VAC 28VAC OFF 24VAC 1b Output voltage switches Selects 24VAC or 28VAC or OFF for each output 1a LED s 1 24 Power LED indicators 1g IEC 320 Connector 115VAC 60Hz 230VAC 50 60Hz grounded line cord included Fig 1 1c Input Voltage Switch Selects 115VAC 230VAC 50 60Hz switch is located on the left side of the unit 115VAC 220VAC 1e Power Outputs 24VAC or 28VAC 1f Output Fuses Automotive blade f...

Page 5: ...14 15 16 9 10 11 12 5 6 7 8 1 2 3 4 21 22 23 24 Main Fuse 13 24 1 2 3 4 N P N P N P N P 5 6 7 8 N P N P N P N P 9 10 11 12 N P N P N P N P 13 14 15 16 N P N P N P N P 17 18 19 20 N P N P N P N P 21 22 23 24 N P N P N P N P Main Fuse 1 12 28VAC OFF 24VAC 28VAC OFF 24VAC AC POWER Fig 2 Typical Hookup ...

Page 6: ...uts not powered RESET ON position Switch illuminated Outputs powered Circuit breaker tripped Switch not illuminated Power LEDs on faceplate are not illuminated Outputs not powered To reset circuit breaker set power switch to the ON RESET position Fig 3 pg 6 The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGERO...

Page 7: ...ft Remove Wall Mount Installation 1 Install mounting brackets A on the left and right side of rack chassis using two 2 flat head screws B included Fig 5a 2 Place unit at desired location and secure with mounting screws not included Fig 5b Caution It is necessary to make sure mounting screws are securely fastened to a beam when installing Fig 5 Fig 5a Fig 5b B A Fig 6 Shelf Installation 1 Position ...

Page 8: ...Notes Altronix is not responsible for any typographical errors 140 58th Street Brooklyn New York 11220 USA phone 718 567 8181 fax 718 567 9056 website www altronix com e mail info altronix com Lifetime Warranty IIVertiLine24 Series K04U MEMBER ...