background image

 

- 6 - 

Vertiline24C

The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the 
user to the presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that 
may be of sufficient magnitude to constitute an electric shock.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of 
important operating and maintenance (servicing) instructions in the literature accompanying
the appliance.

CAUTION: To reduce the risk of electric shock do not open enclosure. 
There are no user serviceable parts inside. 
Refer servicing to qualified service personnel.

1U EIA 19” Rack Mount Chassis 

Mechanical Drawing & Dimensions 

(H x W x D)

:

1.625” x 19.125” x 8.5” (41.3mm x 486mm x 216mm)

OFF

RESET

28VAC

OFF

24VAC

28VAC

OFF

24VAC

17

18

19

20

13

14

15

16

9

10

11

12

5

6

7

8

1

2

3

4

21

22

23

24

28VAC

OFF

24VAC

28VAC

OFF

24VAC

AC POWER

Main Fuse

13-24

1

2

3

4

N P N P N P N P

5

6

7

8

N P N P N P N P

9

10

11

12

N P N P N P N P

13

14

15

16

N P N P N P N P

17

18

19

20

N P N P N P N P

21

22

23

24

N P N P N P N P

Main Fuse

1-12

(ON)

17.125” (435mm)

1.625”

(41.3mm)

8.5”

(215.9mm)

0.95”

(24.1mm)

19.125” (486mm)

Fig. 3
Power switch with built-in circuit breaker:
 

OFF position - Switch not illuminated. Outputs not powered.

 

RESET (ON) position - Switch illuminated. Outputs powered.

 

Circuit breaker tripped - Switch not illuminated. 

 

Power LEDs on faceplate are not illuminated. 

 

Outputs not powered.

 

To reset circuit breaker set power switch to the ON (RESET)

 position 

(Fig. 3, pg. 6).

TOP & BOTTOM

REAR

FRONT

Summary of Contents for Vertiline24C

Page 1: ...s Include Vertiline24C 24VAC or 28VAC 10A Twenty four 24 fuse protected outputs Vertiline246C 24VAC or 28VAC 14A Twenty four 24 fuse protected outputs Vertiline24CD 24VAC or 28VAC 10A Twenty four 24 PTC protected outputs Vertiline246CD 24VAC or 28VAC 14A Twenty four 24 PTC protected outputs ...

Page 2: ...cal Units can be rack wall or shelf mounted Modular 1U standard EIA 19 rack mount chassis Enclosure Dimensions H x W x D approx 1 625 x 19 125 x 8 5 41 3mm x 486mm x 216mm Twenty four 24 Output Rack Mount Configuration Reference Chart Altronix Model Number Output Voltage VAC Total Output Current Power Number of Outputs Output Protection Class 2 Rated Power Limited Output Protection Current max per...

Page 3: ...nal block into the corresponding connector and secure by tightening the screws 9 Upon completion of the wiring set illuminated master power disconnect circuit breaker to the ON RESET position Fig 3 pg 6 10 The power LEDs Green on the faceplate for Outputs 1 24 will illuminate when AC power is present Fig 1a pg 4 If any of these LEDs are off a loss of AC power output may be due to a blown fuse or a...

Page 4: ... 21 22 23 24 N P N P N P N P Main Fuse 1 12 28VAC OFF 24VAC 28VAC OFF 24VAC 1b Output voltage switches Selects 24VAC or 28VAC or OFF for each output 1a LED s 1 24 Power LED indicators 1f IEC 320 Connector 115VAC 60Hz grounded line cord included Fig 1 1d Power Outputs 24VAC or 28VAC 1e Output Fuses Automotive blade fuses Vertiline24C or Vertiline246C rear Vertiline24C Vertiline24CD Vertiline246C or...

Page 5: ... 11 12 5 6 7 8 1 2 3 4 21 22 23 24 Main Fuse 13 24 1 2 3 4 N P N P N P N P 5 6 7 8 N P N P N P N P 9 10 11 12 N P N P N P N P 13 14 15 16 N P N P N P N P 17 18 19 20 N P N P N P N P 21 22 23 24 N P N P N P N P Main Fuse 1 12 28VAC OFF 24VAC 28VAC OFF 24VAC AC POWER Fig 2 Typical Hookup ...

Page 6: ...sis Mechanical Drawing Dimensions H x W x D 1 625 x 19 125 x 8 5 41 3mm x 486mm x 216mm OFF RESET 28VAC OFF 24VAC 28VAC OFF 24VAC 17 18 19 20 13 14 15 16 9 10 11 12 5 6 7 8 1 2 3 4 21 22 23 24 28VAC OFF 24VAC 28VAC OFF 24VAC AC POWER Main Fuse 13 24 1 2 3 4 N P N P N P N P 5 6 7 8 N P N P N P N P 9 10 11 12 N P N P N P N P 13 14 15 16 N P N P N P N P 17 18 19 20 N P N P N P N P 21 22 23 24 N P N P...

Page 7: ...l Mount Installation 1 Install mounting brackets A on the left and right side of rack chassis using two 2 flat head screws B included Fig 5a 2 Place unit at desired location and secure with mounting screws not included Fig 5b Caution It is necessary to make sure mounting screws are securely fastened to a beam when installing Fig 5 B A Fig 5b Fig 5a Fig 6 Shelf Installation 1 Position and affix rub...

Page 8: ...onsible for any typographical errors 140 58th Street Brooklyn New York 11220 USA phone 718 567 8181 fax 718 567 9056 website www altronix com e mail info altronix com Lifetime Warranty Made in U S A IIVertiline24CSeries G23R MEMBER Notes ...

Reviews: