- 2 -

Vertiline3D/VertiLine6D

Overview:

Altronix Vertiline Rack Mount Power Supplies provide eight (8) filtered and electronically regulated power outputs in a
space saving 1U EIA 19” rack mount chassis. The units are available with either 12VDC or 24VDC power outputs.
Vertiline Rack Mount Power Supplies are also available in sixteen (16) outputs. 

Eight (8) Output Rack Mount Configuration Reference Chart:

WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or 
moisture. This installation should be made by qualified service personnel and should conform to
all local codes and in accordance with the National Electrical Code.

Installation Instructions:

1. Attach mounting brackets to Vertiline unit for desired rack or wall mount installation 

(Figs. 3-4, pg. 7)

.

Affix rubber pads to Vertiline for shelf installation 

(Fig. 5, pg. 7)

.

2. Secure the unit into rack, mount unit to wall or place unit on a shelf as desired (unit should be spaced at least

3” from any video monitors). When installing the unit in a rack allow for one half U spacing above the unit
for ventilation.

3. Insert and secure removable terminal blocks to unit 

(Fig. 1e, pg. 4)

.

4. Plug the grounded AC line cord (included) into the IEC 320 connector of the Vertiline unit 

(Fig. 1d, pg. 4)

Insert the plug end of the line cord into a grounded AC, receptacle.

5. Set illuminated master power disconnect circuit breaker to the (ON) position 

(Fig. 1c, pg. 4)

.

6. Measure output voltage before connecting devices. This helps avoid potential damage.
7. Set illuminated master power disconnect circuit breaker to the (OFF) position 

(Fig. 1c, pg. 4)

8. Connect the power output of terminals marked [+ 1 --- ] to the power input of device 

(Fig. 1b, pg. 4)

.

Repeat this step for each additional device (Outputs 2-8).

9. Upon completion of wiring, set illuminated master power disconnect circuit breaker to the 

ON (RESET) position 

(Fig. 1c, pg. 4)

.

• 115VAC 60 Hz input.
• Eight (8) power LED indicators.
• PTC protected outputs.
• Filtered and electronically regulated.
• Illuminated power disconnect circuit breaker with

manual reset.

• IEC 320 - 3-wire grounded line cord (detachable).
• Removable terminal blocks with locking screw flange.
• Ease of installation saves time and eliminates costly labor.
• Compact 1U rack mount chassis.
• Fits standard EIA 19” rack.
• Units can be rack, wall or shelf mounted.

Altronix 
Model
Number

Vertiline3D

12VDC

8 amp

8

PTC

2.5 amp

1.5 amp

Vertiline6D

24VDC

8 amp

8

PTC

2.5 amp

3 amp

Total Output Cur

rent (P

ow

er)

Output 

V

oltage (V

A

C)

Number of Outputs

PTC Output Protection

Cur

rent 

(max. per output)

115V

A

C 60Hz

Input Cur

rent

Agenc

y Listings

VertiLine3D:

• Eight (8) 12VDC power outputs.

VertiLine6D:

• Eight (8) 24VDC power outputs.

VertiLine Specifications:

Common Specifications:

Summary of Contents for Vertiline3D

Page 1: ...Rack Mount Power Supplies Installation Guide Models Include Vertiline3D 12VDC 8 amp Eight 8 PTC protected outputs Vertiline6D 24VDC 8 amp Eight 8 PTC protected outputs Rev 051909 More than just power TM ...

Page 2: ... into a grounded AC receptacle 5 Set illuminated master power disconnect circuit breaker to the ON position Fig 1c pg 4 6 Measure output voltage before connecting devices This helps avoid potential damage 7 Set illuminated master power disconnect circuit breaker to the OFF position Fig 1c pg 4 8 Connect the power output of terminals marked 1 to the power input of device Fig 1b pg 4 Repeat this ste...

Page 3: ... or tripped c One 1 or more power output PTCs are tripped due to a short circuit or overload condition To reset the PTC 1 Set illuminated master power disconnect circuit breaker to the OFF position Fig 1d pg 4 2 Eliminate the trouble condition short circuit or overload 3 Allow 1 minute for PTC to cool off reset 4 Set illuminated master power disconnect circuit breaker to the ON position Fig 1d pg ...

Page 4: ...nnect circuit breaker switch OFF position Circuit breaker tripped Switch not illuminated RESET ON position Switch illuminated 1d IEC 320 Connector 115VAC 60Hz grounded line cord included 1e Removable Terminal Block Fig 1 Vertiline3D and Vertiline6D front Vertiline3D and Vertiline6D rear 1a 1b 1c 1d 1e Removable Terminal Block ...

Page 5: ...Vertiline3D VertiLine6D 5 Fig 2 Typical Application Drawing 12VDC VertiLine3D or 24VDC VertiLine6D Power Outputs to Devices ...

Page 6: ...ker set power switch to the ON RESET position The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the products enclosure that may be of sufficient magnitude to constitute an electric shock The exclamation point within an equilateral triangle is intended to alert the user to the presence of ...

Page 7: ...oth sides of rack chassis Fig 3a 2 Attach mounting brackets A on the left and right side of rack chassis using the two 2 flat head screws B included Fig 3b 3 Install unit into desired EIA 19 rack position and secure with mounting screws not included Fig 3c Fig 5 Fig 4 Shelf Installation 1 Position and affix rubber pads C included at each corner on the bottom of the unit Fig 5 2 Place unit in desir...

Page 8: ... not responsible for any typographical errors Altronix Corp 140 58th Street Brooklyn New York 11220 USA 718 567 8181 fax 718 567 9056 web site www altronix com e mail info altronix com Lifetime Warranty Made in U S A IIVertiline3DSeries E19I Notes ...

Reviews: