background image

- 6 -

Vertiline3D/VertiLine6D

1.625" 

8.5" 

.75" 

19.125" 

17.625" 

(ON)

1U EIA 19” Rack Mount Chassis Mechanical Drawing & Dimensions:

1.625”H x 19.125”W x 8.5”D

TOP & BOTTOM

REAR

FRONT

Illuminated master power disconnect circuit breaker:

OFF position - Switch not Illuminated. Outputs not powered.
RESET (ON) position - Switch illuminated. Outputs powered.
Circuit breaker tripped - Switch not Illuminated. Power LEDs on faceplate
are not illuminated. Outputs not powered.
To reset circuit breaker set power switch to the ON (RESET) position.

The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the
presence of an insulated “DANGEROUS VOLTAGE” within the products enclosure that may be of sufficient
magnitude to constitute an electric shock.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the literature accompanying the appliance.

CAUTION:

To reduce the risk of electric shock do not open enclosure. There are

no user serviceable parts inside. Refer servicing to qualified service personnel.

Summary of Contents for Vertiline3D

Page 1: ...Rack Mount Power Supplies Installation Guide Models Include Vertiline3D 12VDC 8 amp Eight 8 PTC protected outputs Vertiline6D 24VDC 8 amp Eight 8 PTC protected outputs Rev 051909 More than just power TM ...

Page 2: ... into a grounded AC receptacle 5 Set illuminated master power disconnect circuit breaker to the ON position Fig 1c pg 4 6 Measure output voltage before connecting devices This helps avoid potential damage 7 Set illuminated master power disconnect circuit breaker to the OFF position Fig 1c pg 4 8 Connect the power output of terminals marked 1 to the power input of device Fig 1b pg 4 Repeat this ste...

Page 3: ... or tripped c One 1 or more power output PTCs are tripped due to a short circuit or overload condition To reset the PTC 1 Set illuminated master power disconnect circuit breaker to the OFF position Fig 1d pg 4 2 Eliminate the trouble condition short circuit or overload 3 Allow 1 minute for PTC to cool off reset 4 Set illuminated master power disconnect circuit breaker to the ON position Fig 1d pg ...

Page 4: ...nnect circuit breaker switch OFF position Circuit breaker tripped Switch not illuminated RESET ON position Switch illuminated 1d IEC 320 Connector 115VAC 60Hz grounded line cord included 1e Removable Terminal Block Fig 1 Vertiline3D and Vertiline6D front Vertiline3D and Vertiline6D rear 1a 1b 1c 1d 1e Removable Terminal Block ...

Page 5: ...Vertiline3D VertiLine6D 5 Fig 2 Typical Application Drawing 12VDC VertiLine3D or 24VDC VertiLine6D Power Outputs to Devices ...

Page 6: ...ker set power switch to the ON RESET position The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the products enclosure that may be of sufficient magnitude to constitute an electric shock The exclamation point within an equilateral triangle is intended to alert the user to the presence of ...

Page 7: ...oth sides of rack chassis Fig 3a 2 Attach mounting brackets A on the left and right side of rack chassis using the two 2 flat head screws B included Fig 3b 3 Install unit into desired EIA 19 rack position and secure with mounting screws not included Fig 3c Fig 5 Fig 4 Shelf Installation 1 Position and affix rubber pads C included at each corner on the bottom of the unit Fig 5 2 Place unit in desir...

Page 8: ... not responsible for any typographical errors Altronix Corp 140 58th Street Brooklyn New York 11220 USA 718 567 8181 fax 718 567 9056 web site www altronix com e mail info altronix com Lifetime Warranty Made in U S A IIVertiline3DSeries E19I Notes ...