RE6100 Series Installation Guide

IN

STALL

G

U I D E

I

Summary of Contents for Connect Plus RE6100 Series

Page 1: ...Connect Security and Automation Platform RE6100 Series Installation Guide I N STA L L G U I D E I...

Page 2: ...Wi Fi or Ethernet communication channels Control from a user s mobile device Industry leading wireless range Up to 50 users Up to 96 zones 2 way voice communication with RE6130 5 year warranty ITEMS I...

Page 3: ...al the lower mounting hole 4 Connect the panel to the Internet by wiring its Ethernet port to the home router or by installing a Cellular or Wi Fi expansion card or any combination of the above The Wi...

Page 4: ...last sensor is enrolled Enrolling a Keypad or other 2 4GHz peripheral will automatically end wireless enrollment mode Tapping the Enroll WPS button will end wireless enrollment mode 7 Install your sen...

Page 5: ...lowing 1 High ambient noise Ensure the panel is not mounted adjacent to other electronics 2 Panel isn t centrally located or is mounted below ground Move the panel to a central location in the home th...

Page 6: ...beside other electronic devices POTENTIAL FOR INTERFERENCE Put some space between the panel and the home router A 6 foot cable is included for this purpose Trouble beeps can be suppressed so they onl...

Page 7: ...le Sleeping Areas KITCHEN BEDROOM BEDROOM LIVING ROOM BEDROOM DINING BEDROOM Smoke Alarm Placement DINING KITCHEN BEDROOM BEDROOM BEDROOM LIVING ROOM Single Sleeping Area Required Smoke Alarm Optional...

Page 8: ...ear sirens Call for emergency assistance from a safe location Using the Connect Panel System Status Indication is provided via eight LEDs on the front of the panel These LEDs may all be forced OFF to...

Page 9: ...r until the display indicates a panic alarm View real time system status using the Keypad s display Using PINPad See PINPadTM manual for detailed operation Disarm the system by entering a valid user c...

Page 10: ...Power LED on the card is pulsing 2 Inspect the LED on the expansion card A solid LED indicates the panel is connected to the network A flashing LED indicates the panel has found a tower and is attemp...

Page 11: ...ting delay must not exceed 60 seconds Reporting delay is 30 seconds Network Equipment Use a UL 60950 1 listed broadband router modem for the 10 100 Ethernet port or Wi Fi connection CE SYSTEM REQUIREM...

Page 12: ...sor trips for the first sixty seconds after power up Cancel Alarm Enabled Remote Arming Annunciators Enabled SIA Setting Requirements Programmable Options Default Recommended Setting Range Entry Delay...

Page 13: ...is level only 24 hour sensors are active Arming Level Stay Perimeter sensors are active Interior sensors are not active Arming Level Away Perimeter and interior sensors are active Panic Alarm To trigg...

Page 14: ...iren pattern when a smoke test is pressed Test CO detectors by pressing the test button until CO sounds Check mobile app activity to verify CO test signal was reported The sirens will play one cycle o...

Page 15: ...THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 16: ...l replace products that are defective in their first five 5 years IC NOTICE This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions...