PINPad
is a simple arming station that allows local
control of the security system. It is battery powered
and requires no installation tools. Many can be
installed throughout the home to provide convenient
system control.
Features
• Secure 4 digit disarming
• Small yet comfortable
• 5 year warranty
Enroll
by placing the panel into wireless enrollment
mode and then using the specific enrollment
instructions from your Honeywell panel's manual. The
PINPad will be enrolled exactly the same way as a
keyfob.
The default access code
is "1234". To change the
access code, complete the following steps within four
seconds:
1. Enter the current 4-digit access code.
2. Press and hold the "1" and "3" buttons
simultaneously. After three seconds, the Red LED
will be lit.
3. Enter new 4-digit access code. After this happens,
the green LED will be lit.
Panel specific enrollment instructions
Lynx Touch 5100
:
First select "programming". Then
choose "keys" and select "add new".
Key Type
4 Button
User
Master
Serial Number
[
Press Stay key to enroll
]
Zone
49 (example)
Button Key 1 - Zn 49
Arm Away
Button Key 2 - Zn 50
Disarm
Button Key 3 - Zn 51
Arm Stay
Button Key 4 - Zn 52
24 Hour Auxiliary
Use the panel installation guide to verify proper system setup.