Statistic

Unit

GOOD

FAIR

POOR

Wi-Fi Signal 

Strength

dB

Over 39

35 to 39

Under 35

Communication 

Success Rate

%

Over 89

85 to 89

Under 85

Response Time 

Average

ms

Under 200

200 to 250

Over 250

• 

Panel

 (must enter code to access)

• Global Chime - enables or disables panel sensor chime mode
• Quick Arm - arm the panel without entering your access code. Access code is still 

required to disarm.

• Manage Access - manage device users directly from the touchpad (only the account 

owner can modify users, internet access is required)

• 

Edit Installer User - configure the system’s installer access code and password. The 

installer password can be used to connect to a panel via the  
Installer app.

• 

Dealer Code - configure the dealer code used by BAT-Connect to program the system  

Note: 

Only available for Napco panels.

• Push User Pins to Locks - if Z-Wave locks are present, this will erase all existing access 

codes from all door locks, and push all user pin codes to those locks. Pins will be 
cropped to 4 digits before being programmed into the locks.

• UL Compliant Mode - when enabled the and BAT-Connect will adhere to UL 

standards. Dealer or Installer authority is required to configure this option.

• Keypads - lists the panel’s keypads

• Rename keypads by selecting an item on the list and holding it for 2 seconds

• Reset Sensor - when there are sensors that latch open, such as a smoke detectors, they 

can be reset here.

• Communication Test mode 

• The Touchpad will begin testing communications and display "TESTING"
• After one minute, the Touchpad will show the result of the test which will be either 

"GOOD," "FAIR," OR "POOR"

• If you get a "POOR" test result, try the test again from another location
• The table below lists the thresholds used to determine the outcome of the test

• If any statistic falls in the poor range, the test outcome is "POOR"
• If there are no poor statistics and any statistic is in the fair range, the outcome of 

the test is "FAIR"

• If all statistics are in the good range, the outcome of the test is "GOOD"

• Check for updates - this will tell the panel to check for any system updates
• Z-Wave 

• Join/Leave Another Z-Wave Network - the panel can be placed into Z-Wave 

inclusion or exclusion mode to allow it to join/ leave existing Z-Wave networks.

• Soft Reset - a soft reset will reset the Z-Wave controller software. All Z-Wave devices 

will remain enrolled.

• Hard Reset - this action will cause your Z-Wave module to be restored 

back to the default state. Warning: Performing this action results in all Z-Wave 

devices being removed from this Z-Wave controller. To add them back, you will first 

need to exclude them, and then include them again.

**PLEASE SEE Z-WAVE USER GUIDE FOR ADDITIONAL INFORMATION**

• About - lists information about the panel’s installed hardware and software

Summary of Contents for RE667-Pro

Page 1: ...y Verify the Wi Fi card LEDs are on Slot 2 Backup Battery AC Power Input 2 Choose a mounting location Touchpad can be mounted on a wall or tabletop 3 Identify your network and verify signal strength b...

Page 2: ...the enroll button on the side of the panel until it beeps once and then select the desired network Note If connecting to a home network enter router credentials at the Touchpad After a connection is...

Page 3: ...fault Check whether the panel is already full The limit is four Touchpads To confirm number of Touchpads connected log into your account Tap the Restart button to try again BAT Connect cover must be o...

Page 4: ...up the excess power wire into the stand and close the stand cover to contain the wires 4 Plug in power supply 5 If using camera or user management features internet access is required In order to acce...

Page 5: ...nel may be insufficient Wire length must not exceed lengths listed below B Barrel jack of the power supply can be plugged directly into the back of the Touchpad Wires can be routed through wire channe...

Page 6: ...options can be edited by selecting a zone User pin authentication is required Devices Add Remove Z Wave devices using the Add or Remove buttons in the app bar Lock and unlock Z Wave door locks Config...

Page 7: ...and actions More System Status Troubles shows all system troubles If a system trouble condition exists the panel will sound trouble beeps To silence the trouble beeps for 24 hours Go to system page S...

Page 8: ...ification tone Quiet Hours Configure a time period where the Touchpad is quiet Touchpad must enter code to access Firmware Update Available allows user to connect to internet connected Wi Fi net work...

Page 9: ...holding it for 2 seconds Reset Sensor when there are sensors that latch open such as a smoke detectors they can be reset here Communication Test mode The Touchpad will begin testing communications an...

Page 10: ...g on panel Home Screen Functions The headline indicates panel status such as Disarmed or Armed Stay Tap to mute beeps during arm disarm action Tap to view Panic options Tap to turn the Touchpad s disp...

Page 11: ...ounting plate windows if no hole exists The Touchpad display turns off on its own after specified allotted time of inactivity Auto sleep display setting It will turn back on when the screen is touched...

Page 12: ...ne or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different f...

Reviews: