Power PWR 16
Ground GND 17
Data DATA 18
Napco GEM Programming
Compatible Panels
• GEM P800 • GEM P801
1. Set up an account with your interactive service provider.
2. Add a contact that uses the system DEALER CODE to the account before connecting the IGM.
This is required for the IGM to be able to properly configure the system settings.
3. Disarm the system.
4. Program the Napco system using a
DEALER CODE.
5. Exit dealer programming.
6. Power down the panel
7. Set the IGM panel selector switch to
DSC/OTHER.
8. Power up the Napco panel. The IGM will automatically program it. make sure all partitions
are disarmed and dealer programming has been exited.
• Programming starts as soon as a connection is made to the interactive server. Once the
connection is made programming willl last roughly 1 minute.
•
IGM will read Access Code 1, Reporting Code Configuration.
9. The keypad(s) should display
SYSTEM READY.
10. Installation is complete.
Napco Panel
Panel Programming
•
Program zone reporting codes. Programming location 61.
•
Note: The following zone types will be treated as 24-hour zones: (1) Fire, (2) Panic, (4)
Hold- Up (7) Gas Alarm, (8) Heat Alarm, (B) 24-hour alarm
•
Verify the
Dealer Code
entered on the online portal matches the code in the panel.
•
Disable telco reporting for zones 1-8.
IGM