LEVIGATO DRIVES (LG SERIES)
|
LEVIGATO ANTRIEBE (SERIE LG)
|
COMMANDES LEVIGATO (SERIE LG)
27
ADjUSTMENT
Y
ATTENTION!
Before the first programming of the remotes, clean the drive memory from
the previously recorded remotes. If the remote control is absent, the number of the absent
remote control must be deleted from the memory to prevent the unauthorized entry. If the
number of the absent remote control is unknown, delete all numbers of the remotes and re-
record all remote controls.
6.3
SETTINGS Of OPERATION VALUES
The
table 15
shows an example to enter the settings menu and to set the operation values.
1
Press and hold the button
for about 5 secs to enter the
programming mode
2
After the appearance of ‘
P1
’ inscription press the button
or
and select the required menu ‘
P№
’
3
After the appearance of the required menu inscription press the
button
4
With the button
or
select the required setting ‘
f№
’
5
After the appearance of the required setting inscription press the
button
6
The value of setting will be on a display. The value will be with a dot. With the
button
or
select the required value of setting
7
After the appearance of the required value of setting press the button
.
The value will be with a dot, that means the change the setting
8
To exit the programming mode press the button
three times or wait
for 15 seconds (until automatic exit the setup menu)
The
table 16
describes the settings, values of setting and default values for the drive supply.
MENU
SETTING
DESCRIPTION
VALUES
DEfAULT
VALUE
P1
f4
The adjustment of end positions
. The function is
designed to monitor and adjust the end positions
once every 100 cycles of raising and lowering the
gate (
fig.
16)
no
—
Off
/
on
—
ON
no.
P3
f1
Automatic mode
. The control is performed by
means of short presses on the control button
on.
Table 15
Table 16