TR-3019-230E-ICU / TR-3019-400E-ICU
41
41
SETTING THE OPERATION PARAMETERS
Y
ATTENTION!
If
DIP9
switch is set to OFF position and the drive power supply is turned off / on,
the previous additional setting will be deleted and
DIP9-ON
position will be set to the default
value (the additional setting should be made first).
For additional setting, all the operations should be performed sequentially and correctly (
table
6).
If the setting is incorrect, the required deactivation place will not be configured! After the set-
up, a mandatory testing is required.
The setting is performed using the control panel (
fig.
13). During the set-up, the movement con-
trol is performed manually with the button
(by pressing and holding the button).
If you need to interrupt the setting operations and restart the setting again, wait 30 seconds be-
fore auto-exit the set-up mode automatically, or turn off and on the drive supply voltage with
the line circuit-breaker (
fig.
4).
Table
6
ACTION
SETUP OPERATIONS
1
Open doors
position
At the beginning of the setting, the doors should
be fully open. To open the doors, use the control
button
.
ATTENTION
! In Standby mode all movement
blocking devices (STOP) should not be in activation
position until they are set up. The LED of the
control panel should not illuminate continuously
(
table
8)
2
Enter the set-up
mode
Press and hold the button
. Then press both
buttons
simultaneously and hold all
the buttons for at least 3 seconds. When the LED
starts flashing at interval of 1 second, release all
the buttons.
ATTENTION
! When the LED flashes, it means being
in the set-up mode and waiting (up to 30 seconds)
for the next action
3
Enter the set-up
mode to deactivate
input
SE
Press and hold the button
for at least
8 seconds.
When the LED starts flashing rapidly, release the
button
4
Determine
and confirm
deactivation of
input
SE
Press and hold the button
until the doors are
fully closed (the doors will move to the final closing
position and stop). The activation of the device
connected to input
SE
will be set automatically.
After the doors are fully closed (LIMIT CLOSE),
the LED will stop flashing rapidly, illuminate
continuously for 2 seconds, and then fade, which
means that deactivation position of input
SE
is
recorded. Release the button