TR-3019-230E-ICU / TR-3019-400E-ICU
42
42
SETTING THE OPERATION PARAMETERS
ACTION
SETUP OPERATIONS
5
Exit the set-up
mode
Exit to Standby mode will occur automatically after
the LED fades
Y
ATTENTION!
After the set-up, test the security device operation connected to input
SE
, de-
scribed in
table
5 for
DIP9
switch. The obstacle should be on the floor under the optical beams
of advanced optosensors (intersect the beams when closing).
7.2
ADDITIONAL SETTING OF DOORS POSITION
TO DEACTIVATE INPUT «PH»
The additional setting is active only when the final positions are configured (section 6), and
DIP10-ON
and
DIP1-ON
switches are set (the doors are operated in pulse mode).
Y
ATTENTION!
If
DIP10
switch is set to
OFF
position and the drive power supply is turned off / on,
the previous additional setting will be deleted and
DIP10-ON
position will be set to the default
value (the additional setting should be made first).
For additional setting, all the operations should be performed sequentially and correctly (
table
7).
If the setting is incorrect, the required deactivation place will not be configured! After the set-
up, a mandatory testing is required.
The setting is performed by means of the control panel (
fig.
13). During the set-up, the movement
control is performed manually with the buttons
and
(by pressing and holding the button).
If you need to interrupt the setting operations and restart the setting again, wait 30 seconds
before exiting the set-up mode automatically, or turn off and on the drive supply voltage with
the line circuit-breaker (
fig.
4).
Table
7
ACTION
SETUP OPERATIONS
1
Enter the set-up
mode
Press and hold the button
. Then press both
buttons
simultaneously and hold all
the buttons for at least 3 seconds. When the LED
starts flashing at interval of 1 second, release all
the buttons.
ATTENTION
! When the LED flashes, it means being
in the set-up mode and waiting (up to 30 seconds)
for the next action
2
Enter the set-up
mode to deactivate
input
PH
Press and hold the button
for at least
8 seconds.
When the LED starts flashing rapidly, release the
button