background image

ALUZ

1170 North Red Gum Street, Anaheim, CA 92806

Phone: 800 921 2254 or 714 535 7900 | Fax: 714 535 7902 | info@aluz.lighting | aluz.lighting

©

 ALUZ All rights reserved. ALUZ reserves the right to make changes or withdraw specifi cations without prior notice.

Installation Instructions

Page 1 of 11

9 / 1 / 2021 / Rev 0

Square

ZYZY

A1-ZYZY-SQR

Overview

READ ENTIRE GUIDE BEFORE STARTING INSTALLATION

Important Notice:

 

Verify correct luminaire was received with correct 

color temperature, voltage, and wattage before cutting or installing. 

ALUZ will not be responsible if incorrect luminaire is installed.

GENERAL FEATURES

Applications

Surface Mount Direct View

Lens

100% Frosted (No Pixelation: Line of Light)

Length

Built to Order:

 Custom lengths up to 8’  (No Seams)

Specify Overall Length (Minimum: 2’, Maximum: 8’)

Example:

 7’8” = One 7’8” luminaire (Custom Length)

Example:

 3’2” = One 3’2” luminaire (Custom Length)

Example:

 13’6” = 8’ + 5’6”

Example:

 23’8” = 8’ + 8’ + 7’8”

Construction

Aluminum Extrusion

Weight

1.09 lbs per foot

Mounting

Mounting Plates (Sold Separately)

Listing

Dry, Damp, or Wet Location

UL1598, CSA C22.2#250.0

UL8750, CSA250

UL2108, CSA C22.2 #9

Driver

Integral (Driver on Board)

Temperature 

Ratings

Operating / Startup: -20° to 48°C (-4° to 120°F)

Storage: -40° to 76°C (-40° to 170°F)

Installation Link

PRODUCT INFORMATION

• Lighting for direct view and accent lighting.

• Line Voltage 120-277V (UNV) integral drivers .

• Long life, energy effi cient LEDs.

• Choose from a variety of LED colors and whites.

• Can be ordered to specifi c lengths for when exact dimensions are known.

• Electric Hammer Drill

• 14.4 to 28 Volt Cordless Drill         

• Phillips Bits  

• Utility Knife

• Electrical Cord   

               

• Marker 

• Wire Stripper

• Long Nose Pliers

• Drill Bits - Concrete or Wood

• Electrical Three Ways

• Safety Glasses

• Measuring Tape

• Laser Line or Chalk Line 

             

INSTALLATION TOOLS REQUIRED

ELECTRICAL REQUIREMENTS

• Line voltage luminaires do not require a remote driver

• Maximum load per line voltage luminaire is 320 watts per circuit

ELECTRICAL

Dimming

0-10V, DMX, DALI

Maximum Run

(Class 1 Line Voltage 

Integral Driver)

40’ (4W, 5W, 6W, 8W), 26’ (12W)

Luminaire Voltage

120V - 277V (UNV)

END VIEWS / DIMENSIONS

Dry or Damp Location

(No Visible Screws)

3.44”

1.87”

3.44”

1.87”

Wet Location

(Visible Screws)

Summary of Contents for A1-ZYZY-SQR

Page 1: ...ounting Plates Sold Separately Listing Dry Damp or Wet Location UL1598 CSA C22 2 250 0 UL8750 CSA250 UL2108 CSA C22 2 9 Driver Integral Driver on Board Temperature Ratings Operating Startup 20 to 48 C 4 to 120 F Storage 40 to 76 C 40 to 170 F Installation Link PRODUCT INFORMATION Lighting for direct view and accent lighting Line Voltage 120 277V UNV integral drivers Long life energy efficient LEDs...

Page 2: ...rews Do not use improper screw head type on mounting clips It will cause the mounting clip to open up and become dysfunctional Do not modify mounting clips Do not mount fixture with less than the minimum number of mounting clips required See mounting clips section for details Do not force luminaire into a space that is too small Do not force luminaire with cord grip into soffit Fig 3 Do not instal...

Page 3: ...hain connection per DMX 512 RDM standards Do not make DMX wiring connections in parallel When connecting DMX Shield to a DMX controller terminal ensure that it is not connected to or touching earth ground chassis ground and or DC power return Neutral Blue Hot Brown Ground Green Yellow Primary Voltage 120 277V AC DMX Signal DMX White DMX Shield Sleeve DMX Blue DMX WIRING DIAGRAM Dry Location Only D...

Page 4: ...e Bottom Cap to access driver wiring Make wiring connections through hole to conduit by others secured with a conduit fitting rated for the application by others Note Size style and location of conduit and conduit fitting to be determined by installer Remove bottom cap before drilling Do not use Mounting Plate holes for conduit Ensure conduit fitting will not interfere with driver or Mounting Plat...

Page 5: ...GUIDELINES Mounting Plate Laser Line aligned with mounting holes Laser Line 1 Measure area where luminaire will be installed Use a laser line to create a reference line along installation area ensuring consistent alignment of mounting plates Mark location where each mounting plate will be installed along reference line 4 Lay mounting plates and pre drill using an appropriate drill bit for surface ...

Page 6: ...idelines to ensure correct number of Mounting Plates 3 Mark location where Mounting Plates will be installed along laser line Note Mounting holes on Mounting Plates must be aligned with direction of luminaire 4 Lay Mounting Plates and pre drill using proper drill bit for surface and screw size Each mounting plate must be secured to a solid surface such as a wall stud or secured to drywall using dr...

Page 7: ...tice Installation Instructions Page 7 of 11 9 1 2021 Rev 0 Square ZYZY A1 ZYZY SQR Overview 10 If applicable connect disconnects between luminaires and push together leaving no gap 12 Perform a continuity test before connecting luminaire to power source 11 Snap luminaires into Mounting Plates after connecting disconnects Connect disconnects between luminaires Push together leaving no gap Mounted M...

Page 8: ...eeded for each run Refer to Mounting Guidelines to ensure correct number of Mounting Plates 3 Mark location where Mounting Plates will be installed along laser line Note Mounting holes on Mounting Plates must be aligned with direction of luminaire 4 Lay Mounting Plates and pre drill using proper drill bit for surface and screw size Each mounting plate must be secured to a solid surface such as a w...

Page 9: ...e 9 of 11 9 1 2021 Rev 0 Square ZYZY A1 ZYZY SQR Wet Location Mounting 2 of 2 10 If applicable connect disconnects between luminaires and push together leaving no gap For Wet Location applications use the concepts from step 7 9 to create a conduit jumper between luminaire segments 11 Snap luminaires into Mounting Plates after connecting luminaire segments Mounted Mounting Plate Luminaire mounted t...

Page 10: ...sily opened to replace defective driver 4 Loosen hex nut assembly using an 11 32 socket then slide away from slot to release driver Repeat for other side of driver Do not disassemble hex nut assembly 2 Unmount luminaire from mounting clips and remove bottom cap Use a flathead screwdriver to gently pry bottom cap from extrusion 5 Remove defective driver from extrusion and replace with a new compati...

Page 11: ...the short 3 Check to make sure cuts in the lightstrip are clean and not frayed causing positive and negative copper pads to touch 1 Turn off power before beginning Verify power is off by using a non contact circuit tester by others Touch the probe of the tester to the positive wire of the power source The tester will light up if an electrical current is detected 2 Setup your multimeter tester by o...