background image

Installation Instructions

4 / 11 / 2022 / Rev 1

1170 N Red Gum St, Anaheim, CA 92806

©  ALUZ All Rights Reserved. ALUZ reserves the right to make changes or withdraw specifi cations without prior notice.

info@aluz.lighting

aluz.lighting

866.ALUZ.LTG | 714.535.7900

A8 Series 

|

 

LED Tape

ZIZA

 

Standard

(A8-ZIZA-STN)

Page 4 of 12

Driver Functions 

(DMX & DALI Driver - DRV100-E)

STANDALONE OPERATION (Network Operation)

OTHER FUNCTIONS

SET MODE

(HOLD 5 SEC.)

COLR

SHOW

DMX

DALI

DISPLAY OFF

MODE OF OPERATION

• Set Mode to DMX or DALI

1-1L

2-2L

3-3L

4-4L

2-4L

1-4L

RGB

RGBW

RGBA

RRGB

RGGB

CCWW

CWWW

LOG

LIN

LED GROUPS

EXTERNAL INPUT

DIMMING CURVE

DISPLAY OFF

OFF

POTM

10V

SWIT

SET LED GROUPS

• Set LED Groups to RGBW for RGBW lighting.

• Set LED Groups to CCWW for Dynamic White lighting.

• Set External Input to OFF.

• Set Dimming Curve to Linear.

STANDALONE OPERATION (Color / Show)

HUE

0 - 1535

WHITE

0 - 510

INTENSITY

0 - 255

DISPLAY OFF

Color

SHOW

00 - 20

SPEED

-99 - 99

INTENSITY

0 - 255

DISPLAY OFF

Show

•  Standalone Operation should only be used when a control system is 

not present to control the lighting (not recommended).

DMX ADDRESS

NETWORK RESOLUTION

DMX TERMINATION

NETWORK SETUP

INTERPOLATION

1 - 512

8 BT

16 BT

YES

NO

AUTO

MANU

OFF

VID

COLR

WHIT

GLOW

DISPLAY OFF

NO ADDRESS ADDRESS SET

NO. OF BALLASTS

DISPLAY OFF

Set DMX Address

Set DALI Address

•  Consult with a third-party DMX or DALI professional to determine 

which settings are best for your application. ALUZ does not provide 

DMX or DALI commissioning.

NO

SOFT

HARD

LOCK DRIVER

DISPLAY OFF

(HOLD 5 SEC.)

Lock Driver

TEST

DISPLAY OFF

R 1 SEC

G 1 SEC

B 1 SEC

B 1 SEC

W 1 SEC

RGBW 1 SEC

R 1 SEC

G 1 SEC

B 1 SEC

W 1 SEC

RGBW 1 SEC

Visual Test

RESET

PRESS MENU

(HOLD 5 SEC.)

DISPLAY OFF

Reset Settings

•  Always perform the visual test function after wiring to ensure all 

channels are behaving appropriately.

•  Reset driver to factory settings if necessary. It is recommended to reset 

each driver before adjusting settings for the fi rst time.

• Lock driver if applicable (not recommended).

Summary of Contents for A8 Series

Page 1: ...W 21 4 5W Luminaire Voltage 24VDC PRODUCT INFORMATION For accent decorative surface recessed or pendant lighting 24 Volts DC for easy and safe installation Long life energy efficient LEDs Can be ordered to specific lengths for when exact dimensions are known Example 10 x 10 6 Plug and light system Lead wires are typically 36 long and exit on one end ELECTRICAL REQUIREMENTS Luminaires require a 24 Vo...

Page 2: ... feed through wires inside LED Lightstrip will void warranty Ground Fault Circuit Interrupter GFCI protections should be provided on circuits or outlets when LED Lightstrip is used for outdoor applications Surge protector must be set up for electrical power system to avoid damaging LED Lightstrip lighting system Do not connect wires together follow provided wiring diagrams Do not cut wire while en...

Page 3: ...s 001 A DMX Control System by others must be used to operate the lighting The last driver in a daisy chain sequence must be terminated Driver load not to exceed 100W For best dimming performance it is recommended to load drivers to a minimum of 50 50W and a maximum of 80 80W Up to 28 drivers may be daisy chained together using shielded cable specified for DMX wiring Ensure DIP Switch 1 is set to ON...

Page 4: ...FF Color SHOW 00 20 SPEED 99 99 INTENSITY 0 255 DISPLAY OFF Show Standalone Operation should only be used when a control system is not present to control the lighting not recommended DMX ADDRESS NETWORK RESOLUTION DMX TERMINATION NETWORK SETUP INTERPOLATION 1 512 8 BT 16 BT YES NO AUTO MANU OFF VID COLR WHIT GLOW DISPLAY OFF NO ADDRESS ADDRESS SET NO OF BALLASTS DISPLAY OFF Set DMX Address Set DAL...

Page 5: ...ER WIRE SOLDER COVERING WIRE AND PADS WELLER 0 50 SOLDER WIRE SOLDER COVERING WIRE AND PADS COVER CONNECTIONS WITH SILICONE SOLDERING GUIDE 1 Cut lightstrip to desired length Include both sets of solder pads by cutting to the left or right of designated markings allowing more space for soldering 2 Prepare wires by stripping 1 8 from the end of each wire then tin the tips of the wire with solder Ap...

Page 6: ...line and pre drill using an appropriate drill bit for surface material and screw size Typical screw size is 8 32 x 1 Note Allow 1 4 clearance on each side of mounting clip to account for lateral expansion Only install mounting clips on flat even surfaces 3 Space mounting clips evenly throughout the run Example 20 Run 2 Use 1 mounting clip every 2 rounded up Use a minimum of 2 mounting clips per lu...

Page 7: ... disconnects between luminaires or solder connectors using the steps from Application Guidelines 3 Screw extrusions to surface using countersink screws Note Ensure extrusions are aligned Misalignment will prevent lens from snapping in 7 Perform a continuity test before connecting luminaire to power source 2 Lay extrusions along chalk line and drill at least 3 countersink holes per extrusion Drill ...

Page 8: ...n 8 32 x 1 screw Note Allow 0 25 clearance for lateral expansion of assembled mounting clips Only install mounting clips on flat even surfaces 2 Mark location where mounting clips will be installed Note The number of required mounting clips differs for dry and wet location products Verify number of mounting clips is appropriate for installation environment before installing Do not install luminair...

Page 9: ...g clips Mark location where each mounting clip will be installed along reference line 3 Lay mounting clips along reference line and pre drill using an appropriate drill bit for surface and screw size Recommendation 8 32 x 1 screw Note Allow 0 25 clearance for lateral expansion of assembled mounting clips Only install mounting clips on flat even surfaces 2 Mark location where mounting clips will be...

Page 10: ...ht leaks test before connecting luminaire to power source 7 Perform a continuity test before connecting luminaire to power source 1 Measure area where luminaire will be installed Use a laser line to create a reference line along installation area ensuring consistent alignment of mounting channels 3 Screw extrusions to surface using countersink screws Note Ensure extrusions are aligned Misalignment...

Page 11: ... 0 25 clearance for lateral expansion of assembled mounting clips Only install mounting clips on flat even surfaces 2 Mark location where mounting clips will be installed Note The number of required mounting clips differs for dry and wet location products Verify number of mounting clips is appropriate for installation environment before installing Do not install luminaires with inadequate number o...

Page 12: ...positive and negative copper pads to touch 1 Turn power off before beginning Verify power is turned off by using a non contact circuit tester Touch the probe of the tester to positive wire of the power source The tester will light up if an electrical current is detected 2 Setup your tester First insert the black probe lead into the COM jack then insert the red probe lead into the VΩ jack Metal Fla...

Reviews: