Standard Optic

ZIZA

A8-ZIZA-SOP

Overview

GENERAL FEATURES

Applications

Accent, Decorative, Surface, Recess, Pendant Lighting

Lens

Clear, 50% Semi-Frosted, or 100% Frosted

Viewing Angle

15°, 30°, 45°, 60°, 120°, or Asymmetric Optics

Length

Built to Order (+/- 1/8” Tolerance)

Construction

Aluminum Extrusion

Weight

0.271 lbs per foot

Mounting

Mounting Channel or Mounting Clips (Sold Separately)

Listing

Dry, Wet, or IP67 Location

UL2108, CSA C22.2 #9

UL8750, CSA250

Driver

Remote (Sold Separately)

Temperature 

Ratings

Operating / Startup: -20° to 48°C (-4° to 120°F)

Storage: -40° to 76°C (-40° to 170°F)

Installation Link

END VIEWS / DIMENSIONS

.78”

.64”

Clear Lens 

(CL)

50% Semi-Frosted Lens 

(SF)

100% Frosted Lens 

(F)

Optic Lens 

(15D, 30D, 45D, 60D)

.78”

.69”

Asymmetric Lens 

(ASM)

READ ENTIRE GUIDE BEFORE STARTING INSTALLATION

Important Notice:

 

Verify correct luminaire was received with correct 

color temperature, voltage, and wattage before cutting or installing. 

ALUZ will not be responsible if incorrect luminaire is installed.

ELECTRICAL

Dimming

DMX

Maximum Run

(Class 1 Applications)

21’ (5.5W)

26’ (4.5W)

Maximum Run

(Class 2 Applications)

17’ (5.5W)

21’ (4.5W)

Luminaire Voltage

24V DC

PRODUCT INFORMATION

• For accent, decorative, surface, recessed, or pendant lighting.

• 24 Volts DC for easy and safe installation.

• Long life, energy effi cient LEDs.

• Can be ordered to specifi c lengths for when exact dimensions are known

  

Example:

 10 x 10’6”

• Plug and light system.

• Lead wires are typically 36” long and exit on one end.

ELECTRICAL REQUIREMENTS

• Luminaires require a 24 Volt DC remote driver.

• To calculate driver size, determine Watts per Foot.

  

Example:

 4.5W per Foot

• Determine Length in Feet.

  

Example:

 10’

• Calculate Load: Multiply Watts per Foot x Length in Feet

  

Example:

 4.5W x 10’= 45W

• Choose a driver from catalog.

  

Example:

 60 Watt Driver

• Determine maximum driver distance using Maximum Wire Length Table on

  drivers page.

  

Example:

 45 watts is between 40W and 60W. Using #14 wire, maximum distance

  is 37’ from driver to fi rst LED.

• Electric Hammer Drill

• 14.4 to 28 Volt Cordless Drill         

• Phillips Bits  

• Utility Knife

• Electrical Cord   

               

• Marker 

• Wire Stripper

• Long Nose Pliers

• Drill Bits - Concrete or Wood

• Electrical Three Ways

• Safety Glasses

• Measuring Tape

• Laser Line or Chalk Line 

             

INSTALLATION TOOLS REQUIRED

INSTALLATION RECOMMENDATIONS

•  Luminaires must be mechanically attached directly to mounting surface using 

mounting clips, channels, or other appropriate means. Refer to installation step 

by step pages for details.

•  Conduit raceway should be sleeved at one end for low voltage wires going to 

driver.

Summary of Contents for A8-ZIZA-SOP

Page 1: ...mum Run Class 1 Applications 21 5 5W 26 4 5W Maximum Run Class 2 Applications 17 5 5W 21 4 5W Luminaire Voltage 24V DC PRODUCT INFORMATION For accent decorative surface recessed or pendant lighting 24 Volts DC for easy and safe installation Long life energy efficient LEDs Can be ordered to specific lengths for when exact dimensions are known Example 10 x 10 6 Plug and light system Lead wires are typ...

Page 2: ...ires inside LED Lightstrip will void warranty Ground Fault Circuit Interrupter GFCI protections should be provided on circuits or outlets when LED Lightstrip is used for outdoor applications Surge protector must be set up for electrical power system to avoid damaging LED Lightstrip lighting system Do not connect wires together follow provided wiring diagrams Do not cut wire while energized Do not ...

Page 3: ...ine Hot Brown Neutral Blue V V Common Channel 1 Ground Green Line Hot Brown Neutral Blue V V Common Channel 1 DALI Output to next driver if applicable DALI Input from control system by others DALI DALI DALI DALI DALI DALI TYPICAL DAISY CHAIN LAYOUT DALI STATIC COLOR DALI commissioning to be performed by a third party at time of installation ALUZ does not provide DALI commissioning Wire colors on d...

Page 4: ...DE OF OPERATION SET LED GROUPS STANDALONE OPERATION Color Show STANDALONE OPERATION Network Operation HUE 0 1535 WHITE 0 510 INTENSITY 0 255 DISPLAY OFF Color SHOW 00 20 SPEED 99 99 INTENSITY 0 255 DISPLAY OFF Show DMX ADDRESS NETWORK RESOLUTION DMX TERMINATION NETWORK SETUP INTERPOLATION 1 512 8 BT 16 BT YES NO AUTO MANU OFF VID COLR WHIT GLOW DISPLAY OFF Set DMX Address NO ADDRESS ADDRESS SET NO...

Page 5: ...e Solder covering wire and pads Weller 0 50 solder wire Solder covering wire and pads Cover connections with silicone SOLDERING GUIDE 1 Cut lightstrip to desired length Include both sets of solder pads by cutting to the left or right of designated markings allowing more space for soldering 4 Solder lead wires to solder pads on the end of lightstrip Solder the positive wire Red or Black with ridged...

Page 6: ...erial and screw size Typical screw size is 8 32 x 1 Note Allow 1 4 clearance on each side of mounting clip to account for lateral expansion Only install mounting clips on flat even surfaces 3 Space mounting clips evenly throughout the run Example 20 Run 2 Use 1 mounting clip every 2 rounded up Use a minimum of 2 mounting clips per luminaire segment For vertical applications create a stopper at the...

Page 7: ...trusions to surface using countersink screws Note Ensure extrusions are aligned Misalignment will prevent lens from snapping in 2 Lay extrusions along chalk line and drill at least 3 countersink holes per extrusion Drill additional holes as needed 4 After all extrusions have been securely mounted remove adhesive backing from lightstrip and adhere in place along extrusion channel ensuring lightstri...

Page 8: ...ounting clips on flat even surfaces 2 Mark location where mounting clips will be installed Note The number of required mounting clips differs for dry and wet location products Verify number of mounting clips is appropriate for installation environment before installing Do not install luminaires with inadequate number of mounting clips 4 Screw mounting clips to surface then snap extrusions into mou...

Page 9: ...ll using an appropriate drill bit for surface and screw size Recommendation 8 32 x 1 screw Note Allow 0 25 clearance for lateral expansion of assembled mounting clips Only install mounting clips on flat even surfaces 2 Mark location where mounting clips will be installed Note The number of required mounting clips differs for dry and wet location products Verify number of mounting clips is appropri...

Page 10: ...crew extrusions to surface using countersink screws Note Ensure extrusions are aligned Misalignment will prevent lens from snapping in 2 Lay extrusions along chalk line and drill at least 3 countersink holes per extrusion Drill additional holes as needed 4 After all extrusions have been securely mounted remove adhesive backing from lightstrip and adhere in place along extrusion channel ensuring li...

Page 11: ...tall mounting clips on flat even surfaces 2 Mark location where mounting clips will be installed Note The number of required mounting clips differs for dry and wet location products Verify number of mounting clips is appropriate for installation environment before installing Do not install luminaires with inadequate number of mounting clips 4 Screw mounting clips to surface then snap extrusions in...

Page 12: ...itive and negative copper pads to touch 1 Turn power off before beginning Verify power is turned off by using a non contact circuit tester Touch the probe of the tester to positive wire of the power source The tester will light up if an electrical current is detected 2 Setup your tester First insert the black probe lead into the COM jack then insert the red probe lead into the VΩ jack Metal Flakes...