background image

ALUZ

1170 North Red Gum Street, Anaheim, CA 92806

Phone: 800 921 2254 or 714 535 7900 | Fax: 714 535 7902 | info@aluz.lighting | aluz.lighting

©

 ALUZ All rights reserved. ALUZ reserves the right to make changes or withdraw specifi cations without prior notice.

Installation Instructions

Page 11 of 12

9 / 1 / 2021 / Rev 0

Standard Optic

ZIZA

A8-ZIZA-SOP

Mounting Fixture (Wet Location Unassembled Mounting Clips)

MC

Remove adhesive backing

Install lightstrip into extrusions

Lens overlapping

Two extrusions meet

1

Measure area where luminaire will be installed. Use a laser line to create 

a reference line along installation area, ensuring consistent alignment of 

mounting clips. Mark location where each mounting clip will be installed 

along reference line.

3

Lay mounting clips along reference line and pre-drill using an appropriate 

drill bit for surface and screw size. Recommendation: 8/32 x 1” screw.

Note:

 Allow 0.25” clearance for lateral expansion of assembled mounting clips.

Only install mounting clips on flat, even surfaces.

2

Mark location where mounting clips will be installed.

Note: 

The number of required mounting clips differs for dry and wet location 

products. Verify number of mounting clips is appropriate for installation 

environment before installing. Do not install luminaires with inadequate 

number of mounting clips.

4

Screw mounting clips to surface, then snap extrusions into mounting clips.

Note: 

Ensure extrusions are aligned. Misalignment will prevent lens from 

snapping in.

5

After all extrusions have been securely mounted, remove adhesive backing 

from lightstrip and adhere in place along extrusion channel, ensuring 

lightstrip is secure inside extrusion.

Note:

 Refer to Application Guidelines to ensure correct installation.

7

Install lens into extrusion, overlapping where two extrusions meet. Plan 

your cuts so that the lens will always overlap where two extrusions meet. 

Overlapping lenses helps keep extrusions aligned and prevents light leaks.

8

Perform a continuity test before connecting luminaire to power source.

6

If applicable, connect disconnects between luminaires or solder connectors 

using the steps from Application Guidelines.

Summary of Contents for A8-ZIZA-SOP

Page 1: ...mum Run Class 1 Applications 21 5 5W 26 4 5W Maximum Run Class 2 Applications 17 5 5W 21 4 5W Luminaire Voltage 24V DC PRODUCT INFORMATION For accent decorative surface recessed or pendant lighting 24 Volts DC for easy and safe installation Long life energy efficient LEDs Can be ordered to specific lengths for when exact dimensions are known Example 10 x 10 6 Plug and light system Lead wires are typ...

Page 2: ...ires inside LED Lightstrip will void warranty Ground Fault Circuit Interrupter GFCI protections should be provided on circuits or outlets when LED Lightstrip is used for outdoor applications Surge protector must be set up for electrical power system to avoid damaging LED Lightstrip lighting system Do not connect wires together follow provided wiring diagrams Do not cut wire while energized Do not ...

Page 3: ...ine Hot Brown Neutral Blue V V Common Channel 1 Ground Green Line Hot Brown Neutral Blue V V Common Channel 1 DALI Output to next driver if applicable DALI Input from control system by others DALI DALI DALI DALI DALI DALI TYPICAL DAISY CHAIN LAYOUT DALI STATIC COLOR DALI commissioning to be performed by a third party at time of installation ALUZ does not provide DALI commissioning Wire colors on d...

Page 4: ...DE OF OPERATION SET LED GROUPS STANDALONE OPERATION Color Show STANDALONE OPERATION Network Operation HUE 0 1535 WHITE 0 510 INTENSITY 0 255 DISPLAY OFF Color SHOW 00 20 SPEED 99 99 INTENSITY 0 255 DISPLAY OFF Show DMX ADDRESS NETWORK RESOLUTION DMX TERMINATION NETWORK SETUP INTERPOLATION 1 512 8 BT 16 BT YES NO AUTO MANU OFF VID COLR WHIT GLOW DISPLAY OFF Set DMX Address NO ADDRESS ADDRESS SET NO...

Page 5: ...e Solder covering wire and pads Weller 0 50 solder wire Solder covering wire and pads Cover connections with silicone SOLDERING GUIDE 1 Cut lightstrip to desired length Include both sets of solder pads by cutting to the left or right of designated markings allowing more space for soldering 4 Solder lead wires to solder pads on the end of lightstrip Solder the positive wire Red or Black with ridged...

Page 6: ...erial and screw size Typical screw size is 8 32 x 1 Note Allow 1 4 clearance on each side of mounting clip to account for lateral expansion Only install mounting clips on flat even surfaces 3 Space mounting clips evenly throughout the run Example 20 Run 2 Use 1 mounting clip every 2 rounded up Use a minimum of 2 mounting clips per luminaire segment For vertical applications create a stopper at the...

Page 7: ...trusions to surface using countersink screws Note Ensure extrusions are aligned Misalignment will prevent lens from snapping in 2 Lay extrusions along chalk line and drill at least 3 countersink holes per extrusion Drill additional holes as needed 4 After all extrusions have been securely mounted remove adhesive backing from lightstrip and adhere in place along extrusion channel ensuring lightstri...

Page 8: ...ounting clips on flat even surfaces 2 Mark location where mounting clips will be installed Note The number of required mounting clips differs for dry and wet location products Verify number of mounting clips is appropriate for installation environment before installing Do not install luminaires with inadequate number of mounting clips 4 Screw mounting clips to surface then snap extrusions into mou...

Page 9: ...ll using an appropriate drill bit for surface and screw size Recommendation 8 32 x 1 screw Note Allow 0 25 clearance for lateral expansion of assembled mounting clips Only install mounting clips on flat even surfaces 2 Mark location where mounting clips will be installed Note The number of required mounting clips differs for dry and wet location products Verify number of mounting clips is appropri...

Page 10: ...crew extrusions to surface using countersink screws Note Ensure extrusions are aligned Misalignment will prevent lens from snapping in 2 Lay extrusions along chalk line and drill at least 3 countersink holes per extrusion Drill additional holes as needed 4 After all extrusions have been securely mounted remove adhesive backing from lightstrip and adhere in place along extrusion channel ensuring li...

Page 11: ...tall mounting clips on flat even surfaces 2 Mark location where mounting clips will be installed Note The number of required mounting clips differs for dry and wet location products Verify number of mounting clips is appropriate for installation environment before installing Do not install luminaires with inadequate number of mounting clips 4 Screw mounting clips to surface then snap extrusions in...

Page 12: ...itive and negative copper pads to touch 1 Turn power off before beginning Verify power is turned off by using a non contact circuit tester Touch the probe of the tester to positive wire of the power source The tester will light up if an electrical current is detected 2 Setup your tester First insert the black probe lead into the COM jack then insert the red probe lead into the VΩ jack Metal Flakes...

Reviews: