FLASHBACK (flames in the burner tube)
If a flash back occurs (indicated by a roaring noise), immediately
close the cylinder valve.
•
Turn the heater OFF at the control knob.
•
Disconnect the regulator and allow the heater to cool.
•
Check for blockages in the burner head. Clean with com-
pressed air, a small soft brush or pipe cleaners.
•
If the problem persists, have the heater checked by a
qualified technician.
CHANGING YOUR CYLINDER
Make sure you cylinder valve is closed (by turning it clockwise).
Allow the heater to fully cool before replacing the cylinder. Open
the heater to expose the cylinder.
Remove and replace the cylinder.
ALWAYS check that the regulator-sealing washer (nose cone) is
intact and in place before reattaching the
regulator to a cylinder. (Figure B - Page 6)
DO NOT attempt to remove the regulator while the heater is on
or if the cylinder valve is not closed.
14
Summary of Contents for GHP20
Page 1: ......