Page 10
For Assistance: support@alvaradomfg.com +1 (909) 591-8431 PUD4146R1-0
EDM Installation and Maintenance Instructions
1. Using a turnstile lid key, open the cabinet lid.
2. Locate the six-pole primary power terminal block
[Fig. 7].
3.
Using a precision flat-head screwdriver, connect
primary power wires to the appropriate terminals
according to Table 1 [Fig. 7].
Primary Power Wiring Instructions
• Use a licensed electrician for the following steps and adhere to all applicable local codes.
• MAKE SURE PRIMARY POWER IS TURNED OFF AT THE BREAKER.
WARNING
Power
Button
(110VAC version shown)
The following instructions are for fixed turnstile installations only. If you are installing
a portable AC-powered or battery-powered unit, please refer to Appendix B - Portable
Base Turnstile instructions on page 26.
NOTE
Fig. 7
Terminal
110V
220V
L
ine
Black
Brown
N
eutral
White
Blue
G
round
Green
Green/Yellow
Table 1
Connect primary power