Page 14
For Assistance: support@alvaradomfg.com +1 (909) 591-8431 PUD4146R1-0
EDM Installation and Maintenance Instructions
Setting Free Passage Mode (I/O Input - J4 Terminal Block)
Counterclockwise Direction (CCW)
1. Locate the EXTPAS and GND terminals on
the I/O J4 terminal block.
2. Using a wire jumper, connect the EXTPAS
and GND terminals.
Clockwise Direction (CW)
1. Locate the ENTPAS and GND terminals on
the I/O J4 terminal block.
2. Using a wire jumper, connect the ENTPAS
and GND terminals.
CW Direction
CCW Direction
Setting No Passage Mode (I/O Input - J4 Terminal Block)
EXTPAS 1
EXTREJ 2
EXTACC 3
EMROVR 4
GND
5
BDISABLE 6
ALRRST 7
ENTSER 8
ENTOVR 9
GND
10
ENTCLS 11
ENTPAS 12
ENTREJ 13
ENTACC 14
GND
15
J4
EXTPAS 1
EXTREJ 2
EXTACC 3
EMROVR 4
GND
5
BDISABLE 6
ALRRST 7
ENTSER 8
ENTOVR 9
GND
10
ENTCLS 11
ENTPAS 12
ENTREJ 13
ENTACC 14
GND
15
J4
Counterclockwise Direction (CCW)
1. Locate the ENTSER and GND terminals on
the I/O J4 terminal block.
2. Using a wire jumper, connect the ENTSER
and GND terminals.
Clockwise Direction (CW)
1. Locate the ENTCLS and GND terminals on
the I/O J4 terminal block.
2. Using a wire jumper, connect the ENTCLS
and GND terminals.
CCW Direction
CW Direction