PUD4146R1-0
For Assistance: support@alvaradomfg.com +1 (909) 591-8431
Page 15
EDM Installation and Maintenance Instructions
Post-Installation Inspection
NOTE
Perform this post-installation inspection BEFORE powering on the turnstile for the first time.
1.
Anchoring (fixed installations only): Verify the anchor bolts are tensioned to 20 ft-lbs. Tighten if necessary.
2. Dust, Dirt, & Debris: While the unit is powered down, open the lid to reveal the interior electronics. Blow any
dirt, dust, and small debris out of the turnstile with low-pressure compressed air such as Dust-Off.
3. Wiring: Inspect all wires and contacts for exposure to any metal parts that may lead to a short.
Perform the following checks to verify the turnstile is performing properly. Function checks are included for optional
accessories (i.e. User Status lights, Open / Close lights, Local Counters, etc.) and may not be applicable to your
installation. See page 19-20 for details on optional accessories. If any problems are encountered, refer to the
Troubleshooting section on page 24.
Post-Installation Functions Check
Loss of Power Operation
Fig. 11
Perform the following steps to confirm turnstile power-loss
configuration:
1. Power OFF the turnstile.
2. Verify the horizontal drop arm falls [Fig. 11].
3. Power ON the turnstile and verify the dropped
arm rotates and locks back into the home position.
Drop Arm
Powering On
Press the Power Button located on the primary power terminal block [Fig. 7].
The arms will rotate for the duration of the boot up sequence. Before powering on, ensure area is
clear of people and property.
CAUTION