Testing Turnstile Functionality
Perform the following turnstile functionality tests to validate basic turnstile operation.
The following is assumed (Controlled Passage mode tests only):
•
The access control system is operational and all access control wiring to the turnstile is connected.
•
Valid access control cards are on hand for activating the turnstile.
If valid access control cards are not available, use the test buttons located on the control board to simulate an
activation. See page 11 for button location.
See page 20 for location of optional User Status and Open / Close lights.
Test
Procedure
Turnstile Response
Breakaway
• Without providing an activation, push arms
in the direction of passage.
• Arms will rotate small
amount in the direction of
passage and then lock.
• Buzzer will sound.
• Arms reset in two seconds.
Optional Accessories:
• User Status lights change
from yellow to flashing red.
• Open / Close lights change
from green to red.
• Lights reset after two seconds.
Access Time-out
• Provide an activation.
• Do not enter the turnstile
• Wait for the turnstile to time out
(default is 20 seconds.)
Optional Accessories:
• User Status lights change
from yellow to green.
• Lights reset after time-out
period.
• Arms will move a small
amount in the direction of
passage.
• Arms reset to home position
after the time-out period
expires.
Valid Passage
• Provide an activation.
• Rotate the arms in the direction of
passage.
• Arms will move a small
amount in the direction of
passage.
• Arms will complete rotation as
patron walks through.
• Arms will reset to home
position after passage.
Optional Accessories:
• User Status lights change
from yellow to green.
• Lights reset after passage.