PUD4146R1-0
For Assistance: support@alvaradomfg.com +1 (909) 591-8431
Page 27
EDM Installation and Maintenance Instructions
Installing Neutrik Connector to AC Cord
Portable Base Turnstile units do not ship with power cables. Instead, each turnstile ships from the factory with a
disassembled Neutrik connector. Use the connector to create power cables per your facility’s requirements and
specifications.
NOTE
Place the bushing (1) and the chuck (2) over
the cable.
White chuck (a):
6.0 - 11.0 mm
[0.236 - 0.433”]
Black chuck (b):
9.5 - 15.0 mm
[0.374 - 0.59”]
VDE: 9.5 - 14.0 mm
[0.374 - 0.551”]
Prepare the cable as shown.
Cable O.D.
: 6.0 - 15.0 mm
[0.236 - 0.59”]
2
Wire size
: 2.5 mm
(AWG 14)
Insert the wire into the terminals and fasten
the clamping device with a POZIDRIV® #1,
max. Torque 0.5 Nm (0.37 lb-ft).
B
A
B
[0.32"]
8 mm
[0.787”]
20 mm
[0.9”]
PE 23 mm
C
Torque Value 0.5 Nm
POZIDRIV® #1
N
L
WIRING
C
or
1.
2.
b
a
A
Slide the insert and the chuck (1) into the
housing (2).
Important:
Align the chuck by positioning the nose into
(a)
the recess.
Pay attention to the guiding keyway!
(b)
D
D
1.
a
2.
b