Page 28
For Assistance: support@alvaradomfg.com +1 (909) 591-8431 PUD4146R1-0
EDM Installation and Maintenance Instructions
Connecting AC Power to the Portable Turnstile (AC-Powered Option Only)
To connect AC power to the turnstile [Fig. B5]:
1. Lift AC power receptacle cover.
2. Plug the extension cord into the turnstile AC inlet and twist
to lock.
3. Plug other end of the extension cord into an AC power
source
.
This completes the installation process for
Portable AC-Powered turnstiles. Proceed to the
Functions Check on pg. 16 - 17.
AC Inlet
Installing Neutrik Connector to AC Cord (cont.)
Fasten bushing by means of a fork wrench 7/8”
(SW 22), min. Torque 2.5 Nm (1.8 lb-ft).
E
E
Torque Value 2.5 Nm
W rench size
7/8" (SW22)
NA C3FCA
Finished power connector.
REVISIONS
REV.
DESCRIPTION
DATE
BY
D
C
B
A
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
N/A
DRAWN
CHECKED
ENGR
DATE
NAME
TITLE:
SIZE
B
DWG. NO.
REV
SCALE: 1:4
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN INCHES [mm]
ANGULAR: 0.5
.XX [.X] = 0.06 [1.5mm]
.XXX [.XX] = 0.030 [0.76mm]
A
RGM
RPL
9/30/2016
9/30/2016
KIT, MEDCS 110 AC POWER,
NEUTRIK CONNECTOR
SHEET 1 OF 1
DO NOT SCALE DRAWING
6627
E.A.R. #
MATERIAL
NOTES:
BREAK ALL SHARP EDGES.
1.
DIMENSIONS APPLY AFTER FINISH.
2.
MA119766
N/A
APPLICATION/ NEXT ASSY
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
ALVARADO MANUFACTURING INC. ANY
REPRODUCTION IN PART OR AS A
WHOLE WITHOUT THE WRITTEN
PERMISSION OF ALVARADO
MANUFACTURING INC. IS PROHIBITED.
VARIOUS
FINISH
PART NO.
42-2226
THIRD ANGLE PROJECTION
Alvarado Mfg. Co. Inc.
12660 Colony Street, Chino, CA 91710
909.591.8431 - 909.628.1403 (Fax) - www.alvaradomfg.com
Fig. B5