Page 8
For Assistance: support@alvaradomfg.com +1 (909) 591-8431 PUD4146R1-0
EDM Installation and Maintenance Instructions
Electrical Specifications
Environmental Specifications
Pre-Installation Checklist
UL Rated Power Supply
110-120 VAC, 60 Hz or 220-240 VAC, 50 Hz (optional)
Power Requirements
Maximum power consumption is
60W per lane with all options installed.
Operational Voltage
Primary power is stepped down and rectified for low voltage 24VDC, 12VDC, and 5VDC
operation.
Fuse Protection
Primary power is fuse protected (3A/250VAC, slo-blo)
24VDC, 12VDC and 5VDC is fuse protected. The 24VDC power supply is rated for lightning and
industrial surges/per IEC 61000-4-2-5, 6, 8, 11)
It is the installer's responsibility to ensure the following steps are completed before beginning the installation.
1)
All components and hardware to be installed have been unpacked, correctly identified, and moved to the
installation location.
2)
The turnstile configuration and layout has been confirmed with the site manager.
3) Slab, Space, and Conduit requirements have been met.
Operating Temperature
10° to 115° F
-12 to 46° C
Storage Temperature
30° to 160° F
-1 to 71° C
Relative Humidity
90% (non-condensing)
--