Supervisor 2000 Installation Instructions
PUD1601R6-1
For Assistance: support@alvaradomfg.com +1 (909) 591-8431
Page 23
Setting Free Passage Mode (I/O Control Board)
Setting No Passage Mode (I/O Control Board)
Entry Direction
Exit Direction
Exit Direction
Entry Direction
Entry Direction
1. Locate the ENTPAS and GND
terminals.
2. Using a wire jumper, connect the
ENTPAS and GND terminals
[Figure 23].
Exit Direction
1. Locate the EXTPAS and GND
terminals.
2. Use a wire jumper to connect the
EXTPAS and GND terminals
[Figure 23].
Entry Direction
1. Locate the ENTCLS and GND
terminals.
2. Use a wire jumper to connect the
ENTCLS and GND terminals
[Figure 24].
Exit Direction
1. Locate the EXTCLS and GND
terminals.
2. Using a wire jumper, connect the
EXTCLS and GND terminals
[Figure 24].
Figure 23
Figure 24