Supervisor 3500 Installation Instructions
PUD3673R1-1
For assistance: support@alvaradomfg.com +1 (909) 591-8431
Page 17
Anchoring the Turnstile (cont.)
3. Use a pencil and mark each mounting hole location
[Figure 14]. There will be a total of four (4) mounting
holes per cabinet. Remove the cabinets when
complete.
4. Using a 5/8" concrete drill bit, drill the anchor holes
3" in depth at the center of each marked location.
The anchor holes must be clean before installing the
anchor bolts. If the holes are not clear of debris, the
anchor bolts may not tighten correctly.
5. Insert the anchors into each drilled hole [Figure 15].
The threaded end of the anchor must be inserted into
the hole first. Use a hammer to tap the anchors into
place, if needed. Ensure that the anchors are flush
with the concrete floor.
6. If not already done, pull all wires (AC power, access
control and crossover cable) through conduit and
conduit access holes prior to anchoring cabinets.
7. Using clear RTV silicone, seal the gaps between the
conduit and conduit holes.
8.
Maneuver each cabinet over the anchor locations.
Insert four (4) 3/8" x 2-1/2" anchor bolts and flat
washers.
9. Using a torque wrench (ft-lb) and 9/16" socket, torque
the anchor bolts to 80 ft-lbs.
NOTE
Fig. 14
Marking Anchor Holes
Fig. 15
Inserting Anchors
Anchor
Holes
Drill Hole.
Clean Hole.
Vacuum Debris.
Insert the anchors
threaded side
down. The anchors
must be flush with
the surface.
Insert the washer.
Insert the bolt.