TAS12-AS1 & TAS12P-AS1 Installation Instructions

Page 14 

For Assistance: support@alvaradomfg.com  +1 (909) 591-8431 PUD3677R1-0

  Troubleshooting 

Issue

Possible Cause

Solution

The TAS12 display is black with 

horizontal colored lines.

TAS12 display was not initialized 

properly when powering on.

Power OFF the TAS12-AS1 for 10 seconds, 

then power ON [Figure 13].

The TAS12 power cable is not 

seated properly or is damaged.

Check that the power cable is firmly seated in 

the TAS12 power input [Figure 11A]. Inspect 

the cable for damage, replace if necessary. 

The display ribbon cable is not 

seated properly.

Check that the display ribbon cable is firmly 

seated in both connectors [Figure 23].

The power supply is faulty.

Contact Alvarado to obtain a new power 

supply.

The TAS12 display is black and 

the fans are running.

TAS12 display was not initialized 

properly when powering on.

Power OFF the TAS12-AS1 for 10 seconds, 

then power ON [Figure 13].

The TAS12 power cable is not 

seated properly or is damaged.

Check that the power cable is firmly seated in 

TAS12 power input [Figure 11A]. Inspect the 

cable for damage, replace if necessary. 

The display power cable is not 

seated properly.

Check that the display power cable is firmly 

seated in both connectors [Figure 21].

The TAS12 display is faulty.

Replace the TAS12 display.

The TAS12 display is white and 

the fans are running.

TAS12 display was not initialized 

properly when powering on.

Power OFF the TAS12-AS1 for 10 seconds, 

then power ON [Figure 13].

The display ribbon cable is not 

seated properly.

Check that the display ribbon cable is firmly 

seated in both connectors [Figure 23].

The TAS12 power cable is not 

seated properly or is damaged.

Check that the power cable is firmly seated in 

the TAS12 power input [Figure 11A]. Inspect 

the cable for damage, replace if necessary.

The TAS12 display is upside 

down.

DIP switch SW2 on the backplane 

board is improperly configured.

Correctly configure the SW2 DIP switch

 

[Figure 25].

TAS12 touch screen does not 

respond correctly to touch input.

The screen is out of calibration.

Recalibrate the touch screen using the 

TAS12.

The TAS12 touch screen does 

not respond to touch input at all.

TAS12 display was not initialized 

properly when powering on.

Power OFF the TAS12-AS1 for 10 seconds, 

then power ON [Figure 13].

The touch screen board cable is not 

seated properly.

Check that the touch screen board cable is 

firmly seated in both connectors [Figure 24].

   

TAS12 Display

Issue

Possible Cause

Solution

Tickets seem difficult or slow to 

scan.

The scanner window is dirty.

Clean the scanner window.

The scanner does not power on. The scanner power cable is not 

seated properly.

Check that the scanner cable is seated in 

both connectors [Figure 22].

The scanner beeps but the 

operator screen does not display 

the ticket number.

The Ethernet cable is loose or 

damaged.

Reconnect or replace the Ethernet cable 

[Figure 11D].

  

 TAS12 Scanner

After performing a troubleshooting step, make sure to cycle the power to the TAS12-AS1. This re-initializes power to 

the components allowing the change to take effect.

Summary of Contents for TAS12-AS1

Page 1: ...Manufacturing Company Inc 12660 Colony Street Chino CA 91710 Telephone 1 909 591 8431 Fax 1 909 628 1403 support alvaradomfg com www alvaradomfg com TAS12 AS1 TAS12P AS1 PUD3677R1 0 TAS12 AS1 TAS12P...

Page 2: ...n for the installer and operator Please read these instructions For questions please contact Alvarado at 909 591 8431 Monday Friday 6 30am to 4 30 PST Please read this manual completely before install...

Page 3: ...a 1D 2D barcode scanner color TFT display with touchscreen built in speaker and an advanced controller that communicates with Alvarado server applications via wired or wireless TCP IP The TAS12P AS1...

Page 4: ...nsure that all conduit and corresponding lines are installed prior to installing the TAS12 AS1 The conduit stub up location should be dead center of the pedestal The maximum hole size for conduit is 2...

Page 5: ...he anchor holes are not clear of debris the anchor bolts may not tighten correctly 5 Insert one anchor into each drilled hole Figure 3 The threaded end of the anchor must be inserted into the hole fir...

Page 6: ...as needed 9 Using a torque wrench torque the anchor bolts to 20 ft lbs 10 Apply a thick bead of clear RTV silicone around the pedestal base Figure 5 11 Place the two halves of the pedestal base cover...

Page 7: ...etely remove the screws 3 Gently close the pedestal box lid 4 Place the TAS12 onto the lid and slide the unit forward Figure 8 The base plate will act as a guide The dovetail plates will slide under t...

Page 8: ...he terminal block inside the pedestal box Figure 10 2 Remove the protective cover from the terminal block 3 Attach ring connectors to the primary power LINE NEUTRAL and GROUND wires 4 Using a precisio...

Page 9: ...the media reader s USB cable B and plug it into TAS12 USB input B Thermal Printer USB Cable TAS12P AS1 only Allows the TAS12 unit to communicate with the thermal printer 3 Locate the thermal printer...

Page 10: ...ter roughly 885 of paper may be used Contact Zebra for information on custom paper roll stock If you have questions regarding paper compatibility contact Alvarado or Zebra Technical Support for assist...

Page 11: ...r 1 Using a slim object such as a pencil or pen turn on the TAS12 AS1 by pressing the recessed ON OFF button on the rear side of the pedestal box Figure 13 2 Upon powering on the TAS12 AS1 will begin...

Page 12: ...s menu 4 Perform the following Device Tests Figure 17 Set Green LED On Press this button to test the green attendant notification LED Press the button a second time to turn the LED off Set Yellow LED...

Page 13: ...ripe reader with the magnetic stripe facing down Figure 19 The TAS12 will beep when the magnetic stripe has been read After reading the data is sent to the GateLink10 server for validation If the card...

Page 14: ...he TAS12 AS1 for 10 seconds then power ON Figure 13 The display ribbon cable is not seated properly Check that the display ribbon cable is firmly seated in both connectors Figure 23 The TAS12 power ca...

Page 15: ...ernet cable Figure 13 When network connectivity has been reestablished the TAS12 Ethernet port s green LINK light will illuminate The TAS12 s device IP is not recognized by the GateLink10 server or is...

Page 16: ...ructions Page 16 For Assistance support alvaradomfg com 1 909 591 8431 PUD3677R1 0 Troubleshooting cont A Power Supply B Fuse 3A slo blo C Power Button D Primary Power Terminal Block A Fig 20 Pedestal...

Page 17: ...ng cont A Touch Screen Board B Touch Screen Board Cable C Touch Screen Board Ribbon Cable C TAS12 Scanner Cable Fig 22 TAS12 Electronics Assembly Fig 21 TAS12 Touch Screen Board Fig 24 TAS12 Display R...

Page 18: ...2 AS1 TAS12P AS1 Installation Instructions Page 18 For Assistance support alvaradomfg com 1 909 591 8431 PUD3677R1 0 TAS12 Backplane Board Fig 25 Correct DIP SW2 Configuration Fig 24A Troubleshooting...

Page 19: ...PUD3677R1 0 For Assistance support alvaradomfg com 1 909 591 8431 Page 19 Appendix A Plan Elevation and Footprint Drawings TAS12 AS1 12 305 7 178 2 3 58 4 4 111 45 TYPICAL 5 6 142 8X 6 16 ANCHORING HO...

Page 20: ...llation Instructions Page 20 For Assistance support alvaradomfg com 1 909 591 8431 PUD3677R1 0 Appendix A Plan Elevation and Footprint Drawings cont TAS12P AS1 16 1 409 2 3 58 4 4 111 45 TYPICAL 5 6 1...

Page 21: ...AS1 TAS12P AS1 Installation Instructions PUD3677R1 0 For Assistance support alvaradomfg com 1 909 591 8431 Page 21 Revision History Revision Date Author Description 1 0 09 19 2014 A Flores Original do...

Page 22: ...2014 Alvarado Manufacturing Company Inc This work may not be reproduced published or redistributed in whole or in part without the express prior written permission of Alvarado...

Reviews:

Related manuals for TAS12-AS1