background image

To Replace or Reset the Wire

Note: A Phillips screwdriver is needed to replace or reset the wire. 

 

 Start with the blade centered and locked in the middle of the board.

 

Remove the small Phillips screw from wire capture knob (

I

). 

(see 

Figure 4

)

 

 

Loosen wire capture knob enough to thread the wire under the T-bolt (

J

).

 

Thread wire through all four pulleys 

(see 

Figure 5

)

 with ends meeting in  

the middle.

 

Crosswire should go under the wire cover plate (

K

) in the center of the board.  

(see 

Figure 6

)

 

 

Attach spring to loops at each end of wire (

L

). Spring should be in the center of 

the board and should ride above the wire cover plate, not under it.

 

Tighten wire capture knobs and reinsert small Phillips screws. Tighten securely.

1

2

3

4

5

6

7

I

J

K

L

Care and Handling

Keep top adjustment knobs tight to ensure straightedge stays parallel.
Avoid over tightening adjustment knobs or damage may occur.
Clean board surface and underside of blade with mild detergent and soft cloth. Wipe dry.
When transporting or storing the PXB, lock the straightedge at the bottom edge of the board to minimize the chance of damage.
Protect your PXB from damage by storing and transporting in a protective case.
Do not attempt to move straightedge with brakes tightened.
Avoid direct exposure to sunlight and extreme heat.

Figure 4

Figure 5

Figure 6

Wire

capture

knob

T-bolt

Troubleshooting

If straightedge does not slide easily up and down, check that:

Brakes are not dragging
Wires pass properly through pulleys
Pulleys are spinning freely
Spring is not running into pulleys