9.  SPECIFICATIONS 

MODEL 

GES-325V 

GES-425V 

GES-525V 

GES-625V 

Capacity 

350VA 

425VA 

525VA 

625VA 

Voltage 

120V, 220V +/-25% 

INPUT  

Frequency 

50 or 60Hz +/-5% (auto sensing)  

Voltage (on battery) 

Simulated sine wave at Line Input +/-5% 

Frequency (on battery) 

50 or 60Hz +/-0.5% 

Voltage Regulation AVR

±

13% of nominal (120V)  

OUTPUT  

Transfer Time 

2/4 milliseconds, including detection time 

Spike Protection 

320 joules, 2ms 

Overload Protect ion 

UPS automatic shutdown if overload exceeds 110% of 

nominal for 60 second or 130% for 3 seconds.  

Unit Input  

Fuse for overload & short circuit protection 

10BaseT/Modem Line 
Port  

Network (UTP, RJ-45) compatible jacks 

PROTECTION and 
FILTERING 

Short Circuit  

UPS output cut off immediately or input fuse protection

Type 

Maintenance-free, Sealed Lead Acid 

Typical Recharge Time

4 hours (to 90% of full capacity) 

Protection 

Automatic self-test & discharge protection, replace 

battery indicator 

BATTERY 

Back-up Time 

10 - 30 minut es (depending on load)  

Net Weight kg(lbs) 

4.7 (10.4) 

5.8(12.8) 

6.2(13.7) 

6.5(14.3) 

Shipping Weight kg(lbs) 5.0 (11.0) 

6.1(13.4) 

6.5(14.3) 

6.9(15.2) 

Dimension(mm)WxDxH

97x320x135 

PHYSICAL 

Input Inlet  

IEC 320 power inlet  

Battery Back-Up 

Slow beeping sound (about 0.47Hz) 

Battery Low 

Rapid beeping sound (about 1.824Hz) 

ALARM 

Overload 

Continuous beeping sound 

INTERFACE  

RS-232/Dry Contact  

YES 

Safety 

cUL UL1778, CSA C22.2 and FCC Class B 

CONFORMANCE 

Surge 

IEEE C62.41 CAT. A 

Ambient Opertaion 

6,000 meters max. elevation, 0-95% humidity non-

condensing  0-30

°

Audible noise 

<40dBA (1 meter from surface) 

ENVIRONMENT  

Storage Condition 

15000 meters max. elevation 

Specifications subject to change without prior notice to reflect upgrades and 
improvements in technology.

Summary of Contents for GES-325V

Page 1: ...On UPS Systems Inc GES V Series Single Phase Input Single Phase Output Uninterruptible Power Supply GES 325V GES 425V GES 525V GES 625V Line Interactive PWM 325VA 425VA 525VA 625VA User Manual Versio...

Page 2: ...is harmful to the skin and eyes It may be toxic s CAUTION A battery can present a risk of electrical shock and high short circuit current The following precautions should be observed when working on o...

Page 3: ...nance Please follow the precautions below 1 Do not remove the UPS cover unless authorized by factory Removing the cover will void the warranty 2 The UPS can only be connected to a 2 pole 3 wire plug 3...

Page 4: ...RATION 5 4 1 Switching On the UPS 5 4 2 Switching Off the UPS 5 4 3 Self Test 5 4 4 Silence the Alarm 5 4 5 Cold Start 5 4 6 Shutdown Mode 5 4 7 Green Function 6 5 AUDIBLE ALARM 7 5 1 Back Up Slow Ala...

Page 5: ...ur UPS systems is a cyclic self testingfunction to verify both the operation of the UPS and the condition of the battery In addition the V Series UPS provides advanced telephone line and Ethernet surg...

Page 6: ...e than 3 seconds to turn the UPS ON or OFF press and hold the button less than 1 second to activate a self test or silence the back up alarm 2 2 Rear Panel 3 Computer Interface RS 232 Interface is sup...

Page 7: ...This is optional UPS will work properly without a computer interface connection 3 4 Connect to Utility Connect the AC input power connector Included to utility power 3 5 Charging the Battery The UPS...

Page 8: ...ockets accept standard single line telephone connections and 10BaseT connectors This connection will require another length cable This is optional UPS will work properly without this connection 3 8 St...

Page 9: ...eration The LED stops flashing and the LED remains on If the UPS fails the self test it immediately returns to on line operation The loads are unaffected when performing a self test Recharge the batte...

Page 10: ...battery power the UPS will automatically shutdown when in back up mode after 5 minutes if the connected loads are operating at less than 20 watts To disable GREEN FUNCTION press and holdthe On button...

Page 11: ...tion for battery replacement or call your dealer for services 6 SOFTWARE OPTIONS 6 1 UPSMON Software The UPSMON software uses the standard RS 232 interface to perform monitoring functions and then pro...

Page 12: ...usted 3 The ability to turn off the UPS 4 The ability to make the UPS perform a self test Some computers are equipped with a serial connector to link with the communication port in some cases a specia...

Page 13: ...with the bottom turn the entire unit right side up 8 Carefully lift top cover off and place it to the side The connecting wires and electronics will be exposed Be careful not to touch any inner compon...

Page 14: ...all service center to replace batteries UPS has no reaction while AC power is connected yet starts after pushing power on off switch Breaker at back panel open No AC input UPS AC detecting circuit fai...

Page 15: ...ion Type Maintenance free Sealed Lead Acid Typical Recharge Time 4 hours to 90 of full capacity Protection Automatic self test discharge protection replace battery indicator BATTERY Back up Time 10 30...

Page 16: ...nups com Website www alwaysonups com 10 2 QA Warranty Questions Always On UPS Systems Inc Bldg 1 150 Campion Road Kelowna BC Canada V1X 7S8 Phone 250 491 9777 Ext 209 Fax 250 491 9775 Email qa alwayso...

Reviews: