Always “On” UPS Systems Inc. 

 

9

 

Version 1.4

 

9. SPECIFICATIONS 

MODEL Limousin 

II 

Capacity 600VA 

Voltage 

120V, 220V +/-25% 

INPUT 

Frequency 

50 or 60Hz +/-5% (auto sensing) 

Voltage (on battery) 

Simulated sine wave at Line Input +/-5% 

Frequency (on battery) 

50 or 60Hz +/-0.5% 

Voltage Regulation AVR

±

13% of nominal (120V) 

OUTPUT 

Transfer Time 

2/4 milliseconds, including detection time 

Spike Protection 

480 joules, 2ms 

Overload Protection 

UPS automatic shutdown if overload exceeds 110% of 

nominal for 60 second or 130% for 3 seconds. 

Unit Input 

Fuse for overload & short circuit protection 

PROTECTION and 
FILTERING 

Short Circuit 

UPS output cut off immediately or input fuse protection 

Type Maintenance-free, 

Sealed Lead Acid 

Typical Recharge Time 

4 hours (to 90% of full capacity) 

Protection 

Automatic self-test & discharge protection, replace 

battery indicator 

BATTERY 

Back-up Time 

10 - 30 minutes (depending on load) 

Net Weight kg(lbs) 

6.2(13.7) 

Shipping Weight kg(lbs)

6.5(14.3) 

Dimensions 

mm WxDxH 

(inch WxDxH) 

97mm x 320mm x 135mm 

(3.8” x 12.5” x 5.3”) 

PHYSICAL 

Input Inlet 

IEC 320 power inlet 

Battery Back-Up 

Slow beeping sound (about 0.47Hz) 

Battery Low 

Rapid beeping sound (about 1.824Hz) 

ALARM 

Overload 

Continuous beeping sound 

Safety 

cUL UL1778, CSA C22.2 and FCC Class B 

CONFORMANCE 

Surge 

IEEE C62.41 CAT. A 

Ambient Opertaion 

6,000 meters max. elevation, 0-95% humidity non-

condensing 0-40

°

Audible noise 

<40dBA (1 meter from surface) 

ENVIRONMENT 

Storage Condition 

15000 meters max. elevation 

Specifications subject to change without prior notice to reflect upgrades and 
improvements in technology.

Summary of Contents for Limousin II

Page 1: ...Always On UPS Systems Inc Limousin II Single Phase Input Single Phase Output Uninterruptible Power Supply 600VA User Manual Version 1 4...

Page 2: ...and performance of the UPS never load the UPS with a hair dryer heater laser printer or other types of inductive loads 9 The UPS has its own internal energy source battery therefore the output recepta...

Page 3: ...Switching Off the UPS 4 4 3 Self Test 4 4 4 Silence the Alarm 4 4 5 Cold Start 4 4 6 Green Function 4 5 AUDIBLE ALARM 5 5 1 Back Up Slow Alarm 5 5 2 Low Battery Rapid Alarm 5 5 3 Overload Continuous...

Page 4: ...eration of the UPS and the condition of the battery The Limousin provides two single phase 120VAC outlets for ease of connection to you equipment Overload protection is also a feature of this unit The...

Page 5: ...or more than 3 seconds to turn the UPS ON or OFF press and hold the button less than 1 second to activate a self test or silence the back up alarm Figure 2 1 Limousin Front Rear Panel 2 2 Rear Panel 3...

Page 6: ...load into the power outlets on the rear of the Limousin UPS To use the UPS as a master on off switch make sure all of the loads connected to the UPS are switched on CAUTION Never connect a laser print...

Page 7: ...to on line operation On completion of the test the LED stops flashing and remains on If the UPS fails the self test it immediately returns to on line operation If a failure occurred recharge the batte...

Page 8: ...test See replace battery section for battery replacement or call your dealer for services 6 SOFTWARE OPTIONS 6 1 UPSMON Software The UPSMON software uses the standard RS 232 interface to perform monit...

Page 9: ...open files before the battery reserves are exhausted 3 The ability to turn off the UPS 4 The ability to make the UPS perform a self test Some computers are equipped with a serial connector to link wit...

Page 10: ...r off and place it to the side The connecting wires and electronics will be exposed CAUTION Be careful not to touch any inner components of the Limousin UPS when changing the battery Electrical shock...

Page 11: ...center to replace batteries UPS has no reaction while AC power is connected yet starts after pushing power on off switch Fuse at back panel burnt No AC input UPS AC detecting circuit fail Check power...

Page 12: ...ealed Lead Acid Typical Recharge Time 4 hours to 90 of full capacity Protection Automatic self test discharge protection replace battery indicator BATTERY Back up Time 10 30 minutes depending on load...

Page 13: ...nups com Website www alwaysonups com 10 2 QA Warranty Questions Always On UPS Systems Inc Bldg 1 150 Campion Road Kelowna BC Canada V1X 7S8 Phone 250 491 9777 Ext 209 Fax 250 491 9775 Email qa alwayso...

Reviews: