Timekeeper™
Users Manual
01/11/20
Any of the units may have one or more optional buttons, as well as remote triggers/buttons. Some of the remote
keypads are listed below.
•
KP212A – Keypad with 4 buttons, an RS422 jack and 2 optically isolated inputs in surface mount metal
enclosure.
•
KP213A – Keypad with one mushroom button, up to 4 small buttons, an RS422 jack and 2 optically isolated
inputs in an ABS plastic enclosure.
•
KP205A – Keypad with 8 buttons and a knob with RJ11 jacks mounted on a flush mount metal plate.
•
KP205A_GC – Keypad with 8 buttons and a knob, RJ11 jacks and 8 ground closure inputs mounted on a
flush mount metal plate.
•
KP215A – Keypad with 8 buttons and a knob, RS422 jacks and 2 optically isolated inputs mounted on a flush
mount metal plate.
•
KP219A – Keypad with 18 buttons and a knob with RS422 connectors in a metal enclosure.
•
KP219A-RF2 – Keypad with 18 buttons and a knob with built in wireless transmitter and one RS422 input in
a metal enclosure.
•
KP03A, KP04A – Keypad with 4 user configurable buttons in a surface mount metal enclosure. Connects to
the RSSR input on the timer/display.
•
OC002A – Keypad with 2 user configurable buttons and 2 optically isolated inputs in a surface mount metal
enclosure. Connects to the RSSR input on the timer/display.
•
OC004B – Interface module with 4 optically isolated inputs in an ABS plastic enclosure. Connects to the
RSSR input on the timer/display.
•
You can provide your own buttons or connect your machine outputs directly to the RSSR inputs.
•
PS422DB9 – You can connect a PLC, Crestron, AMX or any other device with a serial port to control the
various functions of the Timekeeper™ timer/display.
Connecting multiple Timekeeper™s together
When multiple units are connected together, only one unit may become the controlling unit. The rest of the units
become remote displays.
•
The Timekeeper™ defaults to remote display mode at power up.
•
Be sure to connect the units up such that the controlling unit's transmit port is connected to the receive unit's
receive port.
•
Once a button is pressed, the controlling unit changes to clock/timer mode.
•
The controlling unit remains in timer mode until the power is turned off or a command is received that returns
it to remote display mode.
•
When connecting more than 2 units together, data on the transmit port of a remote display is echoed from the
receive port.
When two units are connected together, in a specific configuration. Either unit can control all of the functions.
•
Connect the transmit port of the first Timekeeper™ to the receive port of the second Timekeeper™.