8.0 TROUBLESHOOTING GUIDE
TROUBLE
REMEDY
POSSIBLE CAUSE
1. Fan rotation backwards.
2. Collector openings not tight
or closed.
3. Fan exhaust area is
restricted.
4. Filter cartridges plugged
with particulate.
a. Filter cartridges need to
be replaced.
b. Lack of compressed air.
1. Check fan rotation.
Rotation should be
clockwise when looking
down at the top of the
blower fan motor. See
Section 5.0, Start-Up.
2. Check the access covers to
make sure that they are in
place and tightened
securely. Also check hopper
discharge area to make
sure that the openings are
closed off and that the
optional hopper
attachments are installed.
3. Check fan exhaust area for
blockage. Remove material
or debris blocking the fan
exhaust area or adjust
damper flow control on fan
exhaust area.
4a. Remove and replace filter
cartridges. See Figure 5,
Filter Cartridge
Replacement and Section
7.1, Filter Cartridges.
Reference the Replacement
Parts List.
4b. Check compressed air
supply for 90 psig
minimum. See Figure 1,
Typical Installation.
Increase pressure as
described in Section 6.0,
Operating Adjustments.
D. Insufficient airflow.