MD Series
10. Specifications
10-7
How to Read the Duty Cycle Graph
Ex.) When performing welding with 6000 A in a temperature of 40
°
C using 1
master and 1 slave (The number of connected devices: 2)
Divide the current value by the number of devices to calculate the current per
device, and then find the weld time referring to the duty cycle graph based on
the obtained current value.
Current per device: 6000 A / 2 devices = 3000 A
3000 A/40
°
C:
Weld time: 8.15 ms
Therefore, in the case of above example, the welding up to 8.15 ms per
second can be performed.
These are duty cycle graphs in 1 m
Ω
load. When the load
capacity changes, the time to perform welding per second
may change, too.
(3) Board List for Maintenance
For repair or replacement, contact us.
Board
Master
Slave
Main control board
ME-3086-13S1
-
Charge board
ME-1876-00
ME-1876-00
Power block board
ME-3102-00
ME-3102-00
Charge control board
ME-3118-00
ME-3118-01
Relay board
AS1157006
AS1157006
(4) Major Components List
Item
Q’ty
Master
Slave
Power transformer
3
2
Fan motor
1
1
Fuse
1
1
Switch
1
1
Thermal protector
21
21
Diode
2
2
FET
200
200
CAUTION