MD Series
6. Explanation of the Screen
6-15
⑳
COMMUNICATION CONTROL
Selects a communication function.
OFF
No communication
DATA
OUTPUT
One-way communication.
The monitor value and error code are output after welding
and in the occurrence of error.
BI-DIRECTION
Two-way communication.
Data is output for the communication request from a
personal computer, etc. Schedules can be changed and
monitor values can be output.
For contents output in communication, refer to
9. External Communication
Function
.
○
21
COMMUNICATION MODE
Selects a communication mode. Valid when COMMUNICATION CONTROL is
set to DATA OUTPUT.
B MODE
Performs the same one-way communication as
MD-A1000B
,
MD-A4000B
,
MD-A8000B
,
MD-B2000B
,
MD-B4000B
, and
MD-C2000B
.
C MODE
Adds the weld time, monitor value of precheck welding,
etc. to B MODE and performs the one-way communication.
For contents output in communication, refer to
9. External Communication
Function
.
○
22
COMMUNICATION UNIT#
Inputs the device No. (ID#). The range is 01 to 31.
When performing the two-way communication between two or more devices,
assign one device No. for one device.
○
23
COMMUNICATION SPEED
Selects a communication speed.
9600
Communication at 9600 bps
19200
Communication at 19200 bps
38400
Communication at 38400 bps
When the communication can not be performed well, slow down the use a
communication speed.
○
24
BACK
Moves to the STATUS (2/2) screen.