background image

Installation and User Instructions for S841 Readers

You should find that the

backplate has holes for

connection to most

standard electrical

backboxes.

With the backplate off (see above), mount

the backplate adjacent to the opening edge

of the door and at a convenient height. Feed

the required cables through the backplate:

The cable from the controller.
The cable from the heater, if used (must

be a separate cable).
A cable from a Remote Interface Module

(RIM), if used. A RIM can reduce cable

lengths to door furniture.

!
!

!

2

The optional heater kit maintains the reader at

the correct temperature when mounted outside.

With the backplate off, remove the backing paper

from the two elements, then stick them to the

inner sides of the reader. The heaters must be

connected to a 24V AC supply (min 25VA).

When mounting outside, the two-part gasket kit

must be fitted:

a) Remove the backplate from the reader by

releasing the two securing screws.

b) Remove the cutouts and backing paper

from the two gaskets, then stick them to the

backplate as shown.

Outer gasket

Inner

gasket

Backplate

securing screws

Backplate

1

Fit the Weatherproofing Kit

Mount the Backplate

Ensure no jumpers are fitted across LK1 (TERM) and LK2 (TEST). If a jumper is provided, park it across

one pin only. LK3 (USER FB) - set to 1 for sound on and 0 for sound off.

3

Reader Links

The S841 is a contactless smart-card reader, with LCD and

keypad, which uses

p

. The S841 is able to read Texas Instruments

(ISO 15693) smart cards, and the card serial number on

Philips MIFARE smart cards.

For either type of card, the S841 supports the use of

unencoded cards (where only the unique card serial number is

read). In the case of Texas Instruments (TI) cards, an encoded

card number can be read. Encoding formats supported include

TI's own formats and the "smartMAX" format.

TM

20mA current loop seudo-random

communications

®

®

Reviews: