background image

SS-AMVC8

 

www.amana-hac.com 

9

www.amana-hac.com 

SS-AMVC8

p

roDuCT

 S

peCiFiCATionS

p

roDuCT

 S

peCiFiCATionS

ADVC8 A

irFlow

 D

ATA

 (

ConT

.)

H

eATing

 S

peeDS

ADVC80603B**

 

(Rise Range: 30° - 60°F)

ADVC80805C*B

 

(Rise Range: 35° - 65°F)

Cooling 

Speed Tap

Adjust 

Tap

Low-Stage 

CFM¹

High-Stage 

CFM¹

Rise 

(°F)

Cooling 

Speed Tap

Adjust 

Tap

Low-Stage 

CFM¹

High-Stage 

CFM¹

Rise 

(°F)

A

Minus (-)

660

945

55

A

Minus (-)

850

1,215

55

Normal

735

1050

49

Normal

945

1,350

49

Plus (+)

810

1155

45

Plus (+)

1,040

1,485

45

B

Minus (-)

725

1035

50

B

Minus (-)

915

1,305

51

Normal

805

1150

45

Normal

1,015

1,450

46

Plus (+)

885

1265

41

Plus (+)

1,115

1,595

42

C

Minus (-)

790

1125

46

C

Minus (-)

975

1,395

48

Normal

875

1250

41

Normal

1,085

1,550

43

Plus (+)

960

1375

38

Plus (+)

1,195

1,705

39

D

Minus (-)

850

1215

43

D

Minus (-)

1,040

1,485

45

Normal

945

1350

38

Normal

1,155

1,650

40

Plus (+)

1040

1485

35

Plus (+)

1,270

1,815

37

ADVC81005C**

 

(Rise Range: 35° - 65°F)

Cooling 

Speed Tap

Adjust Tap

Low-Stage 

CFM¹

High-Stage 

CFM¹

Rise 

(°F)

A

Minus (-)

975

1395

61

Normal

1085

1550

55

Notes

•  These charts are for furnaces installed at 0’- 4,500’. At higher alti-

tudes, a properly de-rated unit will have the same temperature rise 
at a particular CFM, while the ESP at that CFM will be lower.

•   The installation must be adjusted to obtain a temperature rise 

within the range listed on the furnace nameplate.

•   Do not operate above .5” w.c. ESP in heating mode.
•   Propane gas installations will have a high-stage rise approximately 

4°F lower than shown in the tables.

Plus (+)

1195

1705

50

B

Minus (-)

1040

1485

57

Normal

1155

1650

52

Plus (+)

1270

1815

47

C

Minus (-)

1105

1575

54

Normal

1225

1750

49

Plus (+)

1350

1925

44

D

Minus (-)

1135

1620

53

Normal

1260

1800

47

Plus (+)

1385

1980

43

¹  @ .1” to .8” W.C. ESP

C

onTinouS

 F

An

 S

peeDS

Model

Furnace 

Maximum CFM

Continuous 

Fan Speed¹

,

²

ADVC80603B**

1760

530

ADVC80805C**

2000

600

ADVC81005C**

2000

600

¹    Continuous fan speed is 25% of furnace maximum CFM
²    Three continuous fan speeds are possible with the CTK01AA thermostat:  

25%, 50%, and 75% of furnace maximum CFM

Summary of Contents for ADVC8 Series

Page 1: ...Low NOx emissions compliant models available Cabinet Features Fully insulated heavy gauge steel cabinet with durable baked enamel finish Designed for multi position installation upflow horizontal left...

Page 2: ...H High Air ow K Dedicated Up ow Cabinet Width M Up ow Horizontal A 14 B 17 Descrip5on Motor C 21 V Two Stage Variable speed D 24 H Two Stage MulS speed S Single Stage MulS speed Maximum CFM 0 5 ESP E...

Page 3: ...No of Burners 3 4 5 3 4 5 Disposable Filter Size in 610 813 1 016 474 569 711 Electrical Data Min Circuit Ampacity 12 1 12 1 12 1 12 1 12 1 12 1 Max Overcurrent Device amps 15 15 15 15 15 15 Ship Weig...

Page 4: ...utlined in the Installation Manual for additional venting requirements Dimensions Model A B AMVC80604B 17 16 AMVC80805C 21 19 AMVC81005C 21 19 PRODUCT DIMENSIONS 8 AMVC8 GMVC8_____X Alt Gas Inlet High...

Page 5: ...Single Wall Vent SW to be used only as a connector Refer to the venting tables outlined in the Installation Manual for additional venting requirements Auto Comfort Mode During Auto Comfort mode the fu...

Page 6: ...s 1 053 D Minus 1 053 Normal 910 Normal 1 170 Normal 1 170 Plus 1 001 Plus 1 287 Plus 1 287 1 to 8 W C ESP High or Single Stage Cooling Speeds AMVC80604B AMVC80805C AMVC81005C Cooling Speed Tap Adjust...

Page 7: ...High Stage CFM Rise F A Minus 1090 1555 55 Normal 1210 1725 49 Plus 1330 1900 45 B Minus 1105 1575 54 Normal 1225 1750 49 Plus 1350 1925 44 C Minus 1120 1600 53 Normal 1245 1775 48 Plus 1370 1955 44 D...

Page 8: ...Cooling Speed Tap Adjust Tap CFM Cooling Speed Tap Adjust Tap CFM Cooling Speed Tap Adjust Tap CFM A Minus 351 A Minus 468 A Minus 497 Normal 390 Normal 520 Normal 553 Plus 429 Plus 572 Plus 608 B Min...

Page 9: ...age CFM High Stage CFM Rise F A Minus 975 1395 61 Normal 1085 1550 55 Notes These charts are for furnaces installed at 0 4 500 At higher alti tudes a properly de rated unit will have the same temperat...

Page 10: ...10 OUTPUT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1...

Page 11: ...ROLS IND LO 40 VA AUTO RESET AUXILIARY LIMIT CONTROLS YL JUNCTION BLWR PU PURPLE CIRCULATOR BLOWER R 1 GND JUNCTION BOX SWITCH TEMP NEUTRAL 115kBTU MODELS BLOWER COMPARTMENT DOOR SWITCH OPEN WHEN DOOR...

Page 12: ...lity products may mean a change in specifications without notice 2012 Goodman Company L P Houston Texas Printed in the USA Accessories Model Description LPM 06 LP Conversion Kit Springs Orifice AFE18...

Reviews: