Display and Features (some models)

START/+30 SEC
Pad

The START/+30 SEC pad is used to
begin a cooking cycle and to
increase the reheat time in 30 second
increments.

•  The START/+30 SEC pad is used
to reheat for 30 seconds at 100% (full
power). The oven will start
immediately and 30 seconds will be
added to the time counting down
each time the pad is pressed up to a
maximum reheating time of 5
minutes.

NOTE: Pressing the START/+30 SEC
pad is only available in Manual Time
Entry mode.

STOP/RESET Pad

The STOP/RESET pad stops a cooking sequence in progress

and must be pressed again to clear out any remaining cooking time.

When the STOP/RESET pad is used to end a programming change, the
changes are discarded.

Single Pad Programming

This feature enables each numbered pad to be programmed for a specific
cooking cycle. To use this feature, simply program the pad to the desired
length of time and power level. Press the pad once and the microwave will
begin cooking. Number pads 1-10 are preprogrammed at the factory, but can

be changed.

Double Pad
Programming

This feature enables 10 additional programmed entries to be made. Each entry
will be assigned a double digit number. When using the double pad
programming, a pad must be pressed twice within 2 seconds to start the
cooking cycle.

QTY 2X Pad

The QTY 2X pad doubles the preset cooking time. The QTY 2X pad can be
used with either single or double pad programming. Maximum cooking time is
60 minutes except when cooking with full power (100%). In case of full power
(100%), maximum cooking time is 20 minutes.

Stage Cooking

Stage cooking is a cooking sequence with specific power level and time
changes. The user can program up to three different power level changes and
the specific amount of cooking time at each stage. Each power level/cooking
time combination is known as a stage. Stage cooking is available only on
electronic control models. Maximum cooking time is 60 minutes except when
cooking with full power (100%). In case of full power (100%), maximum
cooking time is 20 minutes.

Program Pad

This feature allows you to program a number pad for a specific power level and
cooking time of your choice in any stage cooking.

Power Level Pad

The POWER LEVEL pad allows you to program a cooking cycle for a specific
power level (100%, 80%, 60%, 40%).

PROGRAM

DEFROST

QTY

2X

STOP/

RESET

START/

+30 SEC

CHECK

PROGRAM

POWER

LEVEL

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

START/

+30 SEC

STOP/

RESET

QTY

2X

PROGRAM

17

7

POWER

LEVEL

STAGE--2

STAGE--3

or

11

1

11

1

Summary of Contents for ALD10D

Page 1: ...Model Identification 2 PRECAUTIONS TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY 3 IMPORTANT SAFETY INSTRUCTIONS 3 Grounding Earthing Instructions 5 Installation 5 Display and Features 6 Using the Oven Control Electronic Models 9 Programming the Oven Control Electronic Models 10 Dial Operation 11 Care and Cleaning 12 Before Calling for Service 12 ...

Page 2: ... warranty expires Model Identification When contacting Amana provide product information Product information is located on oven serial plate Record the following information Model Number ____________________________ Manufacturing Number ______________________ Serial or S N Number _______________________ Date of purchase __________________________ Dealer s name and address __________________ ______...

Page 3: ...or its intended use as described in this manual Do not use corrosive chemicals or vapors in this equipment This type of oven is specifically designed to heat cook or dry food It is not designed for industrial or laboratory use 7 As with any equipment CLOSE SUPERVISION is necessary when used by CHILDREN 8 See door cleaning instructions on page 12 of this product safety manual 9 DO NOT heat baby bot...

Page 4: ...Pierce yolk with fork or knife before cooking 3 Pierce skin of potatoes tomatoes and similar foods before cooking with microwave energy When skin is pierced steam escapes evenly 4 Do not operate equipment without load or food in oven cavity 5 Use only popcorn in packages designed and labeled for microwave use Popping time varies depending on oven wattage Do not continue to heat after popping has s...

Page 5: ...d air flow oven may not operate properly and life of electrical parts is reduced B Allow at least 4 10 2 cm between air discharge on back of oven and back wall Oven Clearances WARNING To avoid risk of electrical shock or death this oven must be earthed WARNING To avoid risk of electrical shock or death do not alter the plug Grounding Earthing Instructions Oven MUST be grounded Grounding reduces ri...

Page 6: ...ed a double digit number When using the double pad programming a pad must be pressed twice within 2 seconds to start the cooking cycle QTY 2X Pad The QTY 2X pad doubles the preset cooking time The QTY 2X pad can be used with either single or double pad programming Maximum cooking time is 60 minutes except when cooking with full power 100 In case of full power 100 maximum cooking time is 20 minutes...

Page 7: ...s to deactivate Oven beeps and key graphic disappears from display Power Save Mode This function is used for saving energy by 1 Press and hold CHECK PROGRAM pad for 3 seconds CHECK displays oven beeps and display goes blank 2 To operate oven in Power Save mode press any pad 0 displays and all keypad functions will be the same as in normal mode If keypad is not touched within 10 seconds display wil...

Page 8: ...plays cooking time If stage cooking is programmed total cooking time is displayed DOUBLE Displays when the QTY2X pad is pressed 100 80 60 40 These settings display the current microwave power level used Programming Display DISPLAYS DESCRIPTION Program Displays when oven is in programming mode CHECK Displays when CHECK PROGRAM pad is pressed STAGE _ Displays when programming a specific cooking stag...

Page 9: ...lose door 0 displays Light will turn on 2 Press QTY 2X pad DOUBLE displays 3 Press desired preprogrammed pad or pad sequence example pad 5 PROG 05 displays 4 After 1 second oven begins cooking Displayed cooking time is the total of original cooking time doubled Interrupting Operation Open oven door or press STOP RESET pad to interrupt operation Display continues to show countdown time Close door a...

Page 10: ...POWER LEVEL pad to select desired power level Press POWER LEVEL pad to change power level if desired some models POWER LEVEL displays 100 indicates 100 full microwave power 80 indicates 80 60 indicates 60 and 40 indicates 40 microwave power By continuing to press the Power level pad the power level will cycle through each level continuously 5 Press desired number pad s to program desired cooking t...

Page 11: ... High 77 or High power 100 3 Turn time entry knob clockwise until desired time displays Cooking time can be set up to 10 minutes If turning the timer knob for less than 2 minutes turn it past 2 minutes and then back to the desired time 4 Oven begins operation and time counts down 5 When cooking time elapsed microwave energy stops and oven signal sounds Interrupting Operation Open oven door to inte...

Page 12: ... not accept entries when pad is pressed Make sure oven is on Open and close oven door Press pad again If oven malfunctions or shows E20 E30 Oven control is equipped with a self diagnostic system Self diagnostic system alerts you if there is an error or problem When electronic control signals a problem follow steps listed below 1 Record number shown 2 Unplug oven wait for 1 minute and plug in oven ...