10

PRODUCT DESIGN

Filters:

Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or
CAN/ULCS111 standards. Installing this furnace without filters will void the unit warranty.

This furnace has provisions for the installation of return air filters at the side and/or bottom return. The furnace will
accommodate the following filter sizes depending on cabinet size:

Refer to Minimum Filter Area tables to determine filter area requirement. 

NOTE:

 Filters can also be installed elsewhere in

the duct system such as a central return.

Upflow Filters

Disposable Minimum Filter Area (in

2

)

[

Based on a 300 ft/min filter face velocity]

*Minimum filter area dictated by heating airflow requirement.

Permanent Minimum Filter Area (in

2

)

[Based on 600 ft/min filter face velocity]

*Minimum filter area dictated by heating airflow requirement.

Cabinet

Width

(in.)

Nominal

Filter Size

(in.)

Approx.

Flow Area

(in

2

)

Cabinet

Width

(in.)

Nominal

Filter Size

(in.)

Approx.

Flow Area

(in

2

)

All

16 x 25 x 1

400

17-1/2

14 x 25 x 1

350

21

16 x 25 x 1

400

24-1/2

20 x 25 x 1

500

BOTTOM RETURN 

(1)

SIDE RETURN

 

(1) Flanges on bottom return must be unfolded

Thermostats:

NOTE: Complete lineup of thermostats can be found in the Thermostat Specification Sheets.

600

800

1000

1200

1400

1600

1800

2000

0453BXA*

388*

388*

480

576

---

---

---

---

0703BXA*

---

647*

647*

647*

672

---

---

---

0704CXA*

---

---

583*

583*

672

768

---

---

0904CXA*

---

---

863*

863*

863*

863*

---

---

0905CXA*

---

---

863*

863*

863*

863*

864

---

0905DXA*

---

---

---

777*

777*

777*

864

960

1155DXA*

---

---

---

971*

971*

971*

971*

971*

COOLING AIRFLOW  REQUIREMENT (CFM)

Inpu

t_

_

A

ir

fl

ow

600

800

1000

1200

1400

1600

1800

2000

0453BXA*

194*

194*

240

288

---

---

---

---

0703BXA*

---

324*

324*

324*

336

---

---

---

0704CXA*

---

---

291*

291*

336

384

---

---

0904CXA*

---

---

432*

432*

432*

432*

---

---

0905CXA*

---

---

432*

432*

432*

432*

432*

---

0905DXA*

---

---

---

388*

388*

388*

432

480

1155DXA*

---

---

---

486*

486*

486*

486*

486*

Input

_

_

A

ir

fl

ow

COOLING AIRFLOW  REQUIREMENT (CFM )

Summary of Contents for AMH950453BXA Series

Page 1: ...r part number information Model numbers listed on page 3 Copyright 2007 2009 2010 2012 2013 Goodman Manufacturing Company L P TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU TECHNICAL MANUAL AL AL AL AL This manual is to be used by qualified professionally trained HVAC technicians only Goodman does not assume any responsibility for property damage or personal injury due to improper ser...

Page 2: ... responsible for any injury or property damage arising from improper service or service procedures If you install or perform service on this unit you assume responsibility for any personal injury or property damage which may result Many jurisdictions require a license to install or service heating and air conditioning equipment WARNING WARNING WARNING WARNING is a trademark of Maytag Corporation a...

Page 3: ...ronment and can lead to the imposition of substantial fines These regulations may vary by jurisdiction Should questions arise contact your local EPA office WARNING WARNING Do not connect or use any device that is not design certified by Goodman for use with this unit Serious property damage personal injury reduced unit performance and or hazardous conditions may result from the use of such non app...

Page 4: ...s in Service Instructions General Operation The MH95 furnaces are equipped with an electronic ignition device used to light the burners and an induced draft blower to exhaust combustion products An interlock switch prevents furnace operation if the blower door is not in place Keep the blower access door in place except for inspection and maintenance This furnace is also equipped with a self diagno...

Page 5: ...Line Entrance 14 Flue Pipe Connection Alternate 15 Rubber Elbow 16 Induced Draft Blower 17 Electrical Connection Inlets Alternate 18 Coil Front Cover Pressure Tap 19 Coil Front Cover Drain Port 20 Drain Line Penetrations 21 Drain Trap 22 Blower Door Interlock Switch 23 Capacitor 24 Integrated Control Module with fuse and diagnostic LED 25 24 Volt Thermostat Connections 26 Transformer 40 VA 27 Circ...

Page 6: ...16 D 12 1 8 16 19 3 8 E 13 5 8 17 1 2 20 7 8 SIDE CUT OUT LOW VOLTAGE ELECTRICAL HOLE RIGHT SIDE DRAIN LINE HOLES STANDARD GAS SUPPLY HOLE DRAIN TRAP RIGHT SIDE VIEW HIGH VOLTAGE ELECTRICAL HOLE AIR DISCHARGE 2 C B FRONT VIEW A DISCHARGE UNFOLDED FLANGES FOLDED FLANGES LOW VOLTAGE ELECTRICAL HOLE HIGH VOLTAGE ELECTRICAL HOLE SIDE CUT OUT LEFT SIDE VIEW 19 3 4 AIR INTAKE PIPE 2 PVC LEFT SIDE DRAIN ...

Page 7: ...08 1 10 0130F00000P MH951155DXA 1 30 1 10 0 75 0 60 0 10 20197308 1 10 0130F00000P 2 Data given is the least negative pressure required for pressure switch to remain closed HANG11 44 Orifice HAPS27 16 HAPS27 16 HAPS27 16 HAPS27 16 HANG12 45 Orifice HANG11 44 Orifice NEGATIVE PRESSURE ID BLOWER WITH FLUE FIRING TYPICAL SEA LEVE DATA 2 NEGATIVE PRESSURE COIL COVER WITH FLUE FIRING TYPICAL SEA LEVE D...

Page 8: ...RY LIMIT SWITCHES Part Number 10123514 or 10123533 10123517 Open Setting F 200 210 MH950453BXA 1 MH950703BXA 2 MH950704CXA 2 MH950904CXA 2 MH950905CXA 2 MH950905DXA 2 MH951155DXA 2 ROLLOUT LIMIT SWITCHES Part Number 0130F00105 20162903 20162904 Open Setting F 130 160 150 MH950453BXA 1 MH950703BXA 1 MH950704CXA 1 MH950904CXA 1 MH950905CXA 1 MH950905DXA 1 MH951155DXA 1 PRIMARY LIMIT MH95 XA ...

Page 9: ...lated Z bracket for use with one size smaller furnace All proper coil combinations are subject to being ARI rated with a matched outdoor unit C A P F 1824 A 6 A PRODUCT TYPE C Indoor Coil CABINET FINISH U Unpainted P Painted N Unpainted Case EXPANSION DEVICE F Flowrater NOMINAL CAPACITY RANGE 13 SEER 1824 1 1 2 to 2 Tons 3030 2 1 2 Tons 3636 3 Tons 3642 3 to 3 1 2 Tons 3743 3 to 3 1 2 Tons 4860 4 ...

Page 10: ... filter face velocity Minimum filter area dictated by heating airflow requirement Cabinet Width in Nominal Filter Size in Approx Flow Area in 2 Cabinet Width in Nominal Filter Size in Approx Flow Area in 2 All 16 x 25 x 1 400 17 1 2 14 x 25 x 1 350 21 16 x 25 x 1 400 24 1 2 20 x 25 x 1 500 BOTTOM RETURN 1 SIDE RETURN 1 Flanges on bottom return must be unfolded Thermostats NOTE Complete lineup of t...

Page 11: ...ea level Low firerate is 75 of high fire rate MODEL MH95 0453BXA MH95 0703BXA MH95 0704CXA MH95 0904CXA MH95 0905CXA MH95 0905DXA MH95 1155DXA BTUH Natural Gas Input 46 000 69 000 69 000 92 000 92 000 92 000 115 000 Natural Gas Output 44 200 66 300 66 300 88 400 88 400 88 400 110 500 LP Gas Input 41 400 62 100 62 100 82 800 82 800 82 800 103 500 LP Gas Output 39 800 59 700 59 700 79 600 79 600 79 ...

Page 12: ...1141 52 1094 54 1046 57 973 904 793 MED HI MED LO 2 0 981 61 962 62 943 63 917 65 888 67 830 764 665 LOW 1 5 750 79 730 81 714 83 692 86 657 90 620 570 502 HIGH 4 0 2069 29 1965 30 1871 32 1756 34 1661 36 1549 1415 1275 MH950704CXA MED 3 5 1752 34 1724 34 1667 36 1603 37 1488 40 1402 1290 1082 MED HI MED LO 3 0 1437 41 1437 41 1417 42 1369 43 1320 45 1256 1140 984 LOW 2 5 1184 50 1177 50 1161 51 1...

Page 13: ...10 120 100 130 140 150 100 90 80 70 60 50 40 30 20 10 OUTPUT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1 08 CFM 800 ...

Page 14: ...RESSURE SWITCH N O C GY BK PLUG CONNECTION FIELD SPLICE SWITCH TEMP OR 24V THERMOSTAT CONNECTIONS GR GND 115 VAC 24 VAC BLOWER COMPARTMENT DOOR SWITCH OPEN WHEN DOOR OPEN DOOR SWITCH BK GND L N WH JUNCTION BOX 1 OR ID BLOWER PRESSURE SWITCH HEAT H GND WH RD WH GND BURNER COMPARTMENT BLOWER COMPARTMENT NOTE 4 SEE N O COOL H BK HI BR BR CAPACITOR YL WH YL BL PU RD OR PK BK WH WH BLOWER INDUCED DRAFT...

Page 15: ...WITCH HEAT H GND WH RD WH GND BURNER COMPARTMENT BLOWER COMPARTMENT NOTE 4 SEE N O COOL H BK HI BR BR CAPACITOR YL WH YL CONTROL PRIMARY LIMIT AUTO RESET BL PU MANUAL RESET ROLLOUT LIMIT CONTROL S RD OR PK BK WH WH BLOWER INDUCED DRAFT MANUAL RESET AUXILIARY LIMITS 1 IN UPFLOW BLOWER DECK 2 IN C FLOW BLOWER HOUSING C CIRCULATOR BLOWER FS LIMIT CONTROLS MANUAL RESET AUXILIARY HI HEAT H LO HEAT H IG...

Page 16: ...r to the wiring diagram on the unit for the most up to date wiring MH950905CXA HIGH VOLTAGE DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT MULTIPLE POWER SOURCES MAY BE PRESENT FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE PERSONAL INJURY OR DEATH ...