BLOWER PERFORMANCE SPECIFICATIONS

12

1.

CFM in chart is without filters(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return
filters, this chart assumes both filters are installed.

2.

All furnaces ship as high speed cooling and medium-speed heating. Installer must adjust blower cooling & heating speed as needed.

3.

For most jobs, about 400 CFM per ton when cooling is desirable.

4.

INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.

5.

The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on rating plate. The shaded
area indicates ranges in excess of maximum external static pressure allowed when heating. The data for 0.6" w.c. to 0.8" w.c. is shown for
air conditioning purposes only.

6.

The above chart is for U.S. furnaces installed at 0-2000 feet. At higher altitudes, a properly de-rated unit will have approximately the same
temperature rise at a particular CFM, while the ESP at that CFM will be lower.

*MH95*****XA*

Tons AC

at 0.5"

0.6

0.7

0.8

ESP

CFM

RISE

CFM

RISE

CFM

RISE

CFM

RISE

CFM

RISE

CFM

CFM

CFM

HIGH

3.0

1352

29

1318

30

1260

31

1202

33

1128

35

1044

955

853

*MH950453BXA*

MED 2.5

1214

32

1172

34

1123

35

1064

37

1012

39

938

859

741

(MED-HI)

MED-LO

2.0

997

40

994

40

960

41

923

43

884

45

817

741

611

LOW

1.5

757

52

753

52

734

54

704

56

674

59

620

524

438

HIGH

3.0

1449

41

1409

42

1326

45

1273

47

1201

49

1194

1136

1018

*MH950703BXA*

MED

2.5

1192

50

1172

51

1141

52

1094

54

1046

57

973

904

793

(MED-HI)

MED-LO

2.0

981

61

962

62

943

63

917

65

888

67

830

764

665

LOW

1.5

750

79

730

81

714

83

692

86

657

90

620

570

502

HIGH

4.0

2069

29

1965

30

1871

32

1756

34

1661

36

1549

1415

1275

*MH950704CXA*

MED

3.5

1752

34

1724

34

1667

36

1603

37

1488

40

1402

1290

1082

(MED-HI)

MED-LO

3.0

1437

41

1437

41

1417

42

1369

43

1320

45

1256

1140

984

LOW

2.5

1184

50

1177

50

1161

51

1132

52

1095

54

1047

928

837

HIGH

4.0

1970

40

1874

42

1757

45

1667

48

1566

51

1431

1334

1182

*MH950904CXA*

MED 3.5

1713

46

1650

48

1572

50

1510

52

1418

56

1313

1211

1079

(MED-HI)

MED-LO

3.0

1439

55

1412

56

1370

58

1327

60

1260

63

1166

1078

956

LOW

2.5

1183

67

1155

69

1122

74

1108

72

1062

75

1011

931

816

HIGH

5.0

2058

39

1997

40

1928

42

1852

43

1777

45

1682

1600

1487

*MH950905CXA*

MED 4.0

1718

47

1685

48

1632

49

1586

51

1520

53

1458

1369

1281

(MED-HI)

MED-LO

3.5

1502

54

1464

55

1429

56

1380

58

1319

61

1272

1200

1137

LOW

3.0

1305

62

1277

63

1253

64

1212

66

1175

69

1127

1081

1010

HIGH

5.0

2147

37

2114

37

2057

39

2030

39

1978

40

1889

1784

1713

*MH950905DXA*

MED 4.0

1675

47

1686

47

1640

48

1623

49

1557

51

1501

1455

1360

(MED-HI)

MED-LO

3.5

1489

53

1470

54

1436

55

1409

56

1361

58

1318

1243

1130

LOW

3.0

1307

61

1265

63

1234

64

1203

66

1168

68

1096

1053

991

HIGH

5.0

2134

46

2103

47

2029

48

1941

51

1906

51

1818

1733

1625

*MH951155DXA*

MED 4.0

1678

58

1643

60

1643

60

1577

62

1527

64

1489

1423

1339

(MED-HI)

MED-LO

3.5

1453

68

1440

68

1426

69

1363

72

1349

73

1314

1253

1205

LOW

3.0

1259

78

1239

79

1220

80

1181

83

1159

85

1118

1082

1015

 BLOWER PERFORMANCE

0.1

0.2

0.3

0.4

0.5

(CFM  & Temperature Rise vs. External Static Pressure)

Model

Heating Speed

As Shipped

Motor 

Speed

EXTERNAL STATIC PRESSURE (Inches Water  Column)

Summary of Contents for AMH950453BXA Series

Page 1: ...r part number information Model numbers listed on page 3 Copyright 2007 2009 2010 2012 2013 Goodman Manufacturing Company L P TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU TECHNICAL MANUAL AL AL AL AL This manual is to be used by qualified professionally trained HVAC technicians only Goodman does not assume any responsibility for property damage or personal injury due to improper ser...

Page 2: ... responsible for any injury or property damage arising from improper service or service procedures If you install or perform service on this unit you assume responsibility for any personal injury or property damage which may result Many jurisdictions require a license to install or service heating and air conditioning equipment WARNING WARNING WARNING WARNING is a trademark of Maytag Corporation a...

Page 3: ...ronment and can lead to the imposition of substantial fines These regulations may vary by jurisdiction Should questions arise contact your local EPA office WARNING WARNING Do not connect or use any device that is not design certified by Goodman for use with this unit Serious property damage personal injury reduced unit performance and or hazardous conditions may result from the use of such non app...

Page 4: ...s in Service Instructions General Operation The MH95 furnaces are equipped with an electronic ignition device used to light the burners and an induced draft blower to exhaust combustion products An interlock switch prevents furnace operation if the blower door is not in place Keep the blower access door in place except for inspection and maintenance This furnace is also equipped with a self diagno...

Page 5: ...Line Entrance 14 Flue Pipe Connection Alternate 15 Rubber Elbow 16 Induced Draft Blower 17 Electrical Connection Inlets Alternate 18 Coil Front Cover Pressure Tap 19 Coil Front Cover Drain Port 20 Drain Line Penetrations 21 Drain Trap 22 Blower Door Interlock Switch 23 Capacitor 24 Integrated Control Module with fuse and diagnostic LED 25 24 Volt Thermostat Connections 26 Transformer 40 VA 27 Circ...

Page 6: ...16 D 12 1 8 16 19 3 8 E 13 5 8 17 1 2 20 7 8 SIDE CUT OUT LOW VOLTAGE ELECTRICAL HOLE RIGHT SIDE DRAIN LINE HOLES STANDARD GAS SUPPLY HOLE DRAIN TRAP RIGHT SIDE VIEW HIGH VOLTAGE ELECTRICAL HOLE AIR DISCHARGE 2 C B FRONT VIEW A DISCHARGE UNFOLDED FLANGES FOLDED FLANGES LOW VOLTAGE ELECTRICAL HOLE HIGH VOLTAGE ELECTRICAL HOLE SIDE CUT OUT LEFT SIDE VIEW 19 3 4 AIR INTAKE PIPE 2 PVC LEFT SIDE DRAIN ...

Page 7: ...08 1 10 0130F00000P MH951155DXA 1 30 1 10 0 75 0 60 0 10 20197308 1 10 0130F00000P 2 Data given is the least negative pressure required for pressure switch to remain closed HANG11 44 Orifice HAPS27 16 HAPS27 16 HAPS27 16 HAPS27 16 HANG12 45 Orifice HANG11 44 Orifice NEGATIVE PRESSURE ID BLOWER WITH FLUE FIRING TYPICAL SEA LEVE DATA 2 NEGATIVE PRESSURE COIL COVER WITH FLUE FIRING TYPICAL SEA LEVE D...

Page 8: ...RY LIMIT SWITCHES Part Number 10123514 or 10123533 10123517 Open Setting F 200 210 MH950453BXA 1 MH950703BXA 2 MH950704CXA 2 MH950904CXA 2 MH950905CXA 2 MH950905DXA 2 MH951155DXA 2 ROLLOUT LIMIT SWITCHES Part Number 0130F00105 20162903 20162904 Open Setting F 130 160 150 MH950453BXA 1 MH950703BXA 1 MH950704CXA 1 MH950904CXA 1 MH950905CXA 1 MH950905DXA 1 MH951155DXA 1 PRIMARY LIMIT MH95 XA ...

Page 9: ...lated Z bracket for use with one size smaller furnace All proper coil combinations are subject to being ARI rated with a matched outdoor unit C A P F 1824 A 6 A PRODUCT TYPE C Indoor Coil CABINET FINISH U Unpainted P Painted N Unpainted Case EXPANSION DEVICE F Flowrater NOMINAL CAPACITY RANGE 13 SEER 1824 1 1 2 to 2 Tons 3030 2 1 2 Tons 3636 3 Tons 3642 3 to 3 1 2 Tons 3743 3 to 3 1 2 Tons 4860 4 ...

Page 10: ... filter face velocity Minimum filter area dictated by heating airflow requirement Cabinet Width in Nominal Filter Size in Approx Flow Area in 2 Cabinet Width in Nominal Filter Size in Approx Flow Area in 2 All 16 x 25 x 1 400 17 1 2 14 x 25 x 1 350 21 16 x 25 x 1 400 24 1 2 20 x 25 x 1 500 BOTTOM RETURN 1 SIDE RETURN 1 Flanges on bottom return must be unfolded Thermostats NOTE Complete lineup of t...

Page 11: ...ea level Low firerate is 75 of high fire rate MODEL MH95 0453BXA MH95 0703BXA MH95 0704CXA MH95 0904CXA MH95 0905CXA MH95 0905DXA MH95 1155DXA BTUH Natural Gas Input 46 000 69 000 69 000 92 000 92 000 92 000 115 000 Natural Gas Output 44 200 66 300 66 300 88 400 88 400 88 400 110 500 LP Gas Input 41 400 62 100 62 100 82 800 82 800 82 800 103 500 LP Gas Output 39 800 59 700 59 700 79 600 79 600 79 ...

Page 12: ...1141 52 1094 54 1046 57 973 904 793 MED HI MED LO 2 0 981 61 962 62 943 63 917 65 888 67 830 764 665 LOW 1 5 750 79 730 81 714 83 692 86 657 90 620 570 502 HIGH 4 0 2069 29 1965 30 1871 32 1756 34 1661 36 1549 1415 1275 MH950704CXA MED 3 5 1752 34 1724 34 1667 36 1603 37 1488 40 1402 1290 1082 MED HI MED LO 3 0 1437 41 1437 41 1417 42 1369 43 1320 45 1256 1140 984 LOW 2 5 1184 50 1177 50 1161 51 1...

Page 13: ...10 120 100 130 140 150 100 90 80 70 60 50 40 30 20 10 OUTPUT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1 08 CFM 800 ...

Page 14: ...RESSURE SWITCH N O C GY BK PLUG CONNECTION FIELD SPLICE SWITCH TEMP OR 24V THERMOSTAT CONNECTIONS GR GND 115 VAC 24 VAC BLOWER COMPARTMENT DOOR SWITCH OPEN WHEN DOOR OPEN DOOR SWITCH BK GND L N WH JUNCTION BOX 1 OR ID BLOWER PRESSURE SWITCH HEAT H GND WH RD WH GND BURNER COMPARTMENT BLOWER COMPARTMENT NOTE 4 SEE N O COOL H BK HI BR BR CAPACITOR YL WH YL BL PU RD OR PK BK WH WH BLOWER INDUCED DRAFT...

Page 15: ...WITCH HEAT H GND WH RD WH GND BURNER COMPARTMENT BLOWER COMPARTMENT NOTE 4 SEE N O COOL H BK HI BR BR CAPACITOR YL WH YL CONTROL PRIMARY LIMIT AUTO RESET BL PU MANUAL RESET ROLLOUT LIMIT CONTROL S RD OR PK BK WH WH BLOWER INDUCED DRAFT MANUAL RESET AUXILIARY LIMITS 1 IN UPFLOW BLOWER DECK 2 IN C FLOW BLOWER HOUSING C CIRCULATOR BLOWER FS LIMIT CONTROLS MANUAL RESET AUXILIARY HI HEAT H LO HEAT H IG...

Page 16: ...r to the wiring diagram on the unit for the most up to date wiring MH950905CXA HIGH VOLTAGE DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT MULTIPLE POWER SOURCES MAY BE PRESENT FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE PERSONAL INJURY OR DEATH ...

Reviews: