SS-AMVS80-U
www.amana-hac.com
3
AMVS80
0604BU*
AMVS80
0805CU*
Heating Capacity
Input
60,000
80,000
Natural Gas Output
48,000
64,000
AFUE ¹
80
80
Available AC @ 0.5” ESP
1.5 - 4.0
2.0 - 5.0
Temperature Rise Range (°F)
20 - 50
35 - 65
Circulator Blower
Size (D x W)
10” x 8”
10” x 10”
Horsepower
3/4
3/4
Speed
Variable
Variable
Vent Diameter ²
4”
4”
No. of Burners
1 Burner, 3 tubes
1 Burner, 4 tubes
Minimum Filter Size
(1) 16 x 25
(side or bottom)
(1) 20 x 25 (bottom)
or (2) 16 x 25 (side)
Electrical Data
Min. Circuit Ampacity ³
11.6
11.6
Max. Overcurrent Device (amps) ⁴
15
15
Ship Weight (lbs)
112
127
¹ For Use With Natural Gas Only. For alt 4500’ above sea level, see installation manual.
² DOE AFUE based upon Isolated Combustion System (ICS)
³ Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in
accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
⁴ Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses
or HACR-type circuit breakers of the same size as noted.
Notes
•
All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
•
Gas Service Connection ½” FPT
•
Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical
Code and/or all existing local codes.
AMVS80-U Product Specifications