Component Specifications
RT1300056 Rev.1
October 2000
2
Illustration
Component
Test Procedure
A0282807
Bulb, upper refrigerator/freezer
Volt
Watt
120/125VAC
60 watts
A3079001
Bulb, lower refrigerator
Volt
Watt
115/125 VAC
40 watts
M0360001
Bulb, cavity light
Volt
Watt
115/125 VAC
6 watts
C8931608
Capacitor, auger motor
Volt
Capacitance
210/220 VAC
15 Mfd +10%
-5%
C8931612
Capacitor, compressor run
Volt
Capacitance
220 VAC
15 Mfd +10%
-5%
12049710
Compressor
Type
BTUH
Volt
Watt
Current
Lock rotor
Full load
Resistance
Run Windings
Start Windings
Fan Cooled, R134a refrigerant
850 BTUH
115 VAC, 60 Hz
149 watts
21.3 amps
1.5 amps
2.60 ohms
4.35 ohms
R9900109
Control, damper
Settings
#1
#4
#7
Closing temperatures
47
F
40
F
30
F
R0161092
Control, freezer temperature
Settings
#1
²
in
#1
²
out
#4
²
in
#4
²
out
#7
²
in
#7
²
out
Temperatures
21.0
F
4.5
F
13.3
F
-5.9
F
9.8
F
-11.0
F
!
WARNING
To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before
servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.