Component Specifications
RT1300056 Rev.1
October 2000
4
Illustration
Component
Test Procedure
10097202
Relay, ptc
Resistance
With power off check:
Across terminals 2 & 3
Shorted
Open
4
²
6 ohms
0 ohms
Very high or infinite ohms
12466102
Switch, refrigerator light
Type
Volt
Current
SPDT
125/250 VAC
5.0/5.0 amps
12466101
Switch, freezer light/auger interlock
Type
Volt
Current
DPST, NC
125/250 VAC
5.0 amps
12419601
Switch, limit
Type
Volt
Current
SPST, NO
125/250 VAC
10.0 amps
12017823
Thermostat
Volt
Watt
Current
Resistance across terminals
Above 48° ±5°F
Below 15° ±7°F
Between 48° ±5°F and
15° ±7°F
120/240 VAC
1000 watts
10/5 amps
Open
Closed
Will stay in current state (open or closed)
until either 48° ±6°F or 15° ±8°F is
reached.
10530703
Timer, defrost
Volt
Defrost period (minutes)
Defrost cycle (hours)
120 VAC, 60 Hz
33
3.6
8
12313403
Valve, water (primary)
Volt
Watt
Purple coil
Brown coil
Water pressure (inlet)
Max
Min
Fill rate
120 VAC, 60 Hz
20 watts
20 watts
120 PSI
20 PSI
137 +14 -24 CC's at 7.5 seconds
12313404
Valve, water (secondary)
Volt
Watt
Purple coil
Brown coil
Water pressure (inlet)
Max
Min
Fill rate
120 VAC, 60 Hz
20 watts
20 watts
120 PSI
20 PSI
137 +14 -24 CC's at 7.5 seconds
3
1
4
2
DEFROST
COMPRESSOR
HOT
NEUTRAL
!
WARNING
To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before
servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.