Troubleshooting
October 2000
RT1300056 Rev.1
7
Water Dispenser Rates
Seconds to dispense 10 Oz. Water
Supply Pressure
20 psig*
30 psig*
40 psig*
50 psig*
60 psig*
70 psig*
Filter model with bypass
installed.
18.1
14.3
12.2
10.8
9.8
9.0
Filter model with new filter
installed.
22.0
17.3
14.2
12.8
11.5
10.4
*Amana specifies a minimum supply pressure of 35 psig for water filter units. Minimum pressure requirement is to insure water valves close and
sufficient water volume is available to fill ice maker. Proper fill is 140 cc of water in 7.5 seconds. Failure of water valves to close because of low
pressure will result in icemaker fill-tube freeze-up or dripping at cavity.
Ice ‘N Water
Electronic Dispenser Control
Ice Dispenser Operation
Select
CRUSHED
or
CUBED
mode by pushing the button on the dispenser panel. A green indicator light above the
button indicates the current selection. Selection mode may not be changed while ice dispenser is in operation.
Dispenser Light
Light activates at full power when dispensing ice or water. A sensor activates light at half-power when light level
around refrigerator is low. Activate or deactivate sensor by pushing
AUTO LIGHT
button located on control façade.
Green light above
AUTO LIGHT
button indicates sensor is active.
Dispenser Lock
Prevents operation of water and ice dispensers. To activate or deactivate lock, press and hold
DISPENSER LOCK
button for 3 seconds. Green light above button indicates dispenser lock.
Automatic Lock Out
Shuts down both ice and water mechanisms of dispenser when either mechanism has run continuously for 5
minutes. To return power to dispenser, press and hold
DISPENSER LOCK
for 3 seconds. Auger motor shuts off
automatically after 3 minutes of continuous operation. After about 3 minutes in shut-off state, auger motor resets
automatically.
Filter Status Light
Filter light reminds user to replace water filter after cumulative flow exceeds filter capacity. Green light indicates filter
in good condition. Change light indicates filter replacement needed. Once filter light turns red, it remains red until
reset. To reset filter indicator, press both
DISPENSER LOCK
and
AUTO LIGHT
buttons simultaneously and hold 4
seconds. Green light will flash 3 times when indicator resets.
NOTE: Filter status light turns red after cumulative flow exceeds filter capacity even if bypass is installed and unit is
used without filter cartridge.
FILTERED WATER
FILTERED ICE
CRUSHED
CUBED
AUTO LIGHT
DISPENSER LOCK
LIGHT
SENSOR
OK
CHANGE