45
RS5280001 Rev. 0
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a 10,000 ohm resistor before attempting
to service. Ensure all earthing wires are connected before certifying unit as repaired and/or operational.
!
WARNING
NOTE:
Install new or reuse compressor grommets in
reassembly.
Condenser
1.
See
Compressor, Condenser, Condenser Fan
Access.
2.
See
Condenser Fan Motor,
steps 1-3.
NOTE:
Condenser is only available as assembly with
base pan.
3.
Unbraze compressor from condenser and unbolt
compressor from base pan and partially remove.
4.
Remove base pan from unit and remove the
condenser fan motor shroud, condensate drain
pan, capacitor, and wiring harness.
Remount these components during reassembly.
Drain Tube and Drain Elbow
1.
Remove machine compartment rear cover and
heat exchanger cover.
2.
Remove two screws securing condenser fan
shroud to outer case back, if necessary.
3.
Remove drain tube mounting screws at drain
elbow and pull tube off elbow and out of locator
clamp in machine compartment.
4.
Remove three mounting screws securing elbow to
top wall and pry elbow out through back wall.
Disassembly